Some encoders contain a Power Failure Bit (PFB):
With LA10 the PFB is always „low“.
Figure 5: Readout of data (2-time with 25 clocking)
7.3 Interface CANopen
The measuring system with a CAN interface is equipped in compliance with CANopen
Standard DS406. A NMT command is issued to start the communication.
The following identifiers are given:
CAN - Identifier
(6 Byte telegram)
181 (16) = Identifier
First 4 bytes = Position (Resolution 0.001 mm), Baud rate 250 KB/s
Following 2 bytes = speed in mm/s
Not inverted SSI clock
Position
LSB
MSB
LSB
MSB
Byte:
0
1
2
3
4
5
Speed
PFB = Power failure bit
T = Cycle duration of clock pulse
Tm = Monoflop time > 15 μ
s