Limes LA10 / BA1
Absolute Magnetic Length Measurement System
7.3.1 Process Data Transmission
The
2 PDO services
PDO1 (tx) and PDO2 (tx) are available for process data transmission. A
PDO transmission can be
asynchronously
(event-driven) or by a change in the process value
of the sensor data.
Standard setting for the Mapping of the transmit PDO1&2:
Mapping
TPDO1 (1800h)
TPDO2 (1801h)
Mapping object
1A00h
1A01h
Entry
0x60040020
0x60300110
Object
6004h
6030h
Subindex
00
00
Data length
20h (32 Bit)
10h (16 Bit)
Asynchronous
Asynchronous
Transmit PDO 1 (1800h) / Position asynchronous
Default COB-ID is 180 + Node number: Example 180h + 3Fh = 1BFh
Nachricht
Byte 0
Byte 1
Byte 2
Byte 3
1BF
Position LSB
XX
XX
Position MSB
The position values can have a maximum value of 0 – (2
32
- 1).
Transmit PDO2 (1801h) / Speed
Default COB-ID is 280 + Node number: Example 280h + 3Fh = 2BFh
Message
Byte 4
Byte 5
2BF
Speed LSB
Speed MSB
The speed can have a maximum value of 0 – (2
16
- 1).