background image

 

ROTEX

®

 SP "Non Sparking" 

Operating/Assembly instructions 

KTR-N 
Sheet: 
Edition: 

40228 EN 
7 of 28 

 

Please observe protection 

note ISO 16016. 

Drawn: 

2019-10-10 Pz/Bru 

Replacing: 

KTR-N dated 2017-01-02 

Verified: 

2019-10-10 Pz 

Replaced by: 

 

 

 

 

Illustration 7: Type ZS-DKM-C (No. 085) 

 

Table 7: Type ZS-DKM-C (No. 085) 

Size 

Drop-

out 

center 
length  

L [mm] 

Spider 

1)

 

(component 

2) 

Rated torque 

[Nm] 

Dimensions [mm] 

Component 7.5/7.6 steel (St) 

Dimensions 

[mm] 

Component 

6c Al-H 

3)

 

Max. 

finish 

bore d 

2)

 

L

total

 

l

1

l

2

 

x

1

x

2

 

D

H

 

D

A

 

d

H

 

T

A

 

[Nm] 

d

B

 

l

11

 

24 

100 

35 

28 

145 

30  22.5  18  14  2.0 

55 

61 

27 

M6 

14 

14 

49 

140 

185 

89 

28 

100 

95 

38 

151 

35  25.5  20  15  2.5 

65 

72 

30 

M8 

35 

16 

41 

140 

191 

81 

38 

100 

190 

45 

171 

45  35.5  24  18  3.0 

80 

87 

38 

M8 

35 

22 

33 

140 

211 

73 

42 

100 

265 

55 

178 

50 

39 

26  20  3.0 

95 

85 

103  46  28  M10 

69 

30 

26 

140 

218 

66 

48 

140 

310 

60 

230 

56 

45 

28  21  3.5  105 

95 

114  51  32  M12 

120 

35 

62 

55 

140 

410 

70 

240 

65 

50 

30  22  4.0  120  110  130  60  37  M12 

120 

40 

50 

180 

280 

90 

200 

300 

110 

65 

140 

625 

80 

260 

75 

60 

35  26  4.5  135  115  146  68  47  M12 

120 

48 

40 

180 

300 

 

 

 

 

 

 

 

 

 

 

 

 

80 

1)  Maximum torque of the coupling T

Kmax.

 = rated torque of the coupling T

K rated

 x 2; transmittable torque as per 92 ShA-GS 

2)  Bores H7 with keyway to DIN 6885 sheet 1 [JS9] and setscrew 
3)  Size 42 with drop-out center length L=100 mm made of steel 

 

 

Illustration 8 

Type 7.5

 

clamping hub type DH without feather keyway for  
double-cardanic combination 

 

Type 7.6

 

clamping hub type DH with feather keyway for  
double-cardanic combination 

 

 

Hubs, clamping hubs or similar types (type 7.5) without feather keyways may be used in 
category 3 only and are marked with category 3 accordingly. 

 

 

ROTEX

®

 couplings with attachments that can generate heat, sparks and static charging 

(e. g. combinations with brake drums, brake disks, overload systems such as torque 
limiters, fan impellers etc.) are not permitted for the use in potentially explosive 
atmospheres. 
A separate analysis must be performed. 

 

Technical data 

Содержание E4-DKM

Страница 1: ...rified 2019 10 10 Pz Replaced by ROTEX SP Non Sparking Single cardanic Torsionally flexible jaw couplings type GN GND EN and their combinations according to directive 2014 34 EU Type GN No 080 Type GN...

Страница 2: ...2 6 Reference to EC Machinery Directive 2006 42 EC 10 3 Storage transport and packaging 10 3 1 Storage 10 3 2 Transport and packaging 11 4 Assembly 11 4 1 Components of the couplings 11 4 2 Advice fo...

Страница 3: ...03 1b 151 75 995 48 310 1 62 140 56 28 21 3 5 105 51 95 32 1c 55 56 114 1b 164 80 105 55 410 1 74 160 65 30 22 4 0 120 60 110 37 1c 65 65 130 1b 185 90 120 65 625 1 80 185 75 35 26 4 5 135 68 115 47 1...

Страница 4: ...ted torque Nm Dimensions mm 3 Component 1c Max finish bore d1 2 L l1 l2 E b s DA dH a 24 35 28 78 30 18 14 2 0 61 27 4 28 95 32 90 35 20 15 2 5 72 30 38 190 42 114 45 24 18 3 0 87 38 42 265 48 126 50...

Страница 5: ...51 75 995 48 310 1 62 140 56 28 21 3 5 105 51 95 32 5c 40 60 36 114 1b 164 80 105 55 410 1 74 160 65 30 22 4 0 120 60 110 37 5c 45 66 40 130 1b 185 90 120 65 625 1 80 185 75 35 26 4 5 135 68 115 47 5c...

Страница 6: ...6 Max finish bore d2 2 l1 l2 l3 l4 DA a Ltotal DH dH l11 E b s 24 35 20 22 46 61 4 0 96 55 27 16 18 14 2 0 28 95 22 26 53 72 4 0 110 65 30 18 20 15 2 5 38 190 28 30 62 87 4 0 128 80 38 20 24 18 3 0 4...

Страница 7: ...5 62 55 140 410 70 240 65 50 30 22 4 0 120 110 130 60 37 M12 120 40 50 180 280 90 200 300 110 65 140 625 80 260 75 60 35 26 4 5 135 115 146 68 47 M12 120 48 40 180 300 80 1 Maximum torque of the coupl...

Страница 8: ...54 1 79 0 99 3 18 66 8 123 0 123 0 195 6 286 3 41 7 68 6 48 1 70 2 88 2 19 70 5 129 8 129 8 206 5 302 2 39 5 64 9 45 6 66 5 83 6 20 74 2 136 7 136 7 217 4 318 1 318 1 37 5 61 7 43 3 63 2 79 4 71 1 22...

Страница 9: ...ly injuries that may result in death Warning of product damages This symbol indicates notes which may contribute to preventing material or machine damage General advice This symbol indicates notes whi...

Страница 10: ...The transmittable torque of the shaft hub connection must be reviewed by the customer and is subject to his responsibility For drives subject to torsional vibrations drives with cyclic stress due to...

Страница 11: ...wise contractually agreed packaging will follow the in house packaging specifications of KTR The coupling is generally supplied in individual parts Before assembly the coupling has to be inspected for...

Страница 12: ...KM No 086 Component Quantity Description Illustration 12 Type E4 DKM No 086 2 2 Spider 92 ShA 3 2 Setscrews DIN EN ISO 4029 5bc 2 E4 hub SP 6 1 DKM spacer Components of ROTEX type ZS DKM C No 085 Comp...

Страница 13: ...a setscrew according to DIN EN ISO 4029 with a cup point or an end plate to fasten the hubs axially Only valid with type ZS DKM C Please provide for a setscrew or an end plate to fasten the hubs axial...

Страница 14: ...ns frequently alternating torsional direction shock loads etc The keyway should preferably be located between the cams With axial fastening by the setscrew the tapped hole should be located on the key...

Страница 15: ...ee table 9 If the shaft diameters with inserted feather key are smaller than dimension dH see table 1 to 5 of the spider one or two shaft ends may protude into the spider Illustration 15 Assembly of t...

Страница 16: ...ntil the hub bodies with the half shells fit closely to the shaft Shift the DH clamping hubs in axial direction until the dimension Ltotal is achieved see illustration 22 and table 7 Secure the DH cla...

Страница 17: ...e accurate the alignment of the coupling the longer is its service life If used in potentially explosive atmospheres for explosion group IIC only half of the displacement figures see table 12 to 14 ar...

Страница 18: ...1 0 1 0 1 1 0 75 0 85 1 10 1 40 1 60 2 00 2 30 Table 13 Displacement figures type E4 DKM No 086 Size 24 28 38 42 48 55 65 Max axial displacement Ka mm 1 4 1 5 1 8 2 0 2 1 2 2 2 6 1 0 1 4 1 4 2 0 2 0 2...

Страница 19: ...The coupling must not operate in an accumulation of dust For covers with unlocked openings on the top face no light metals must be used if the couplings are used as equipment of equipment group ll if...

Страница 20: ...sive atmospheres Elimination Different operating noise and or vibrations occuring Misalignment Increased temperature on the spider surface ignition risk by hot surfaces 1 Set the unit out of operation...

Страница 21: ...pling components and replace coupling components that have been damaged 4 Insert spider assemble coupling components 5 Inspect alignment adjust if necessary 6 Inspect and adjust ambient contact temper...

Страница 22: ...oupling fails Contact addresses of the KTR partners for spare parts and orders can be obtained from the KTR homepage at www ktr com KTR does not assume any liability or warranty for the use of spare p...

Страница 23: ...30 C to 75 C 95 C T6 30 C to 60 C 80 C Explanation The maximum surface temperatures each result from the maximum permissible ambient or operating temperature Ta plus the maximum temperature increase T...

Страница 24: ...according to the table Breakdowns if possible The maintenance intervals must be adjusted to the modified operating parameters without fail M2 2G 2D Gases and vapours of explosion group IIC The torsio...

Страница 25: ...cur an inspection must be made with the machine stopped Reaching the limits for replacing depends on the operating conditions and the existing operating parameters In order to ensure a long service li...

Страница 26: ...er without aluminium Category 3 hubs resp clamping hubs without feather keyway ROTEX Year I M2 Ex h I Mb II 3G Ex h IIC T6 T4 Gc II 3D Ex h IIIC T80 C T110 C Dc 30 C Ta 60 C 90 C KTR Systems GmbH Carl...

Страница 27: ...DKM C only Complete marking valid for PUR only II 2G c IIC T6 T5 resp T4 30 C Ta 65 C 80 C resp 90 C II 2D c T 110 C I M2 c 30 C Ta 90 C Substance group gases fogs and vapours The marking with explosi...

Страница 28: ...afety and health requirements according to enclosure II of directive 2014 34 EU The coupling described in here complies with the specifications of the following standards rules DIN EN ISO 80079 36 DIN...

Отзывы: