3. Program and Operation
3.6.4 Calibration Setup
- Set calibration mode for Manual / Auto using the joystick [
▶
].
- In manual mode, select {Calibration} to execute {Calibration} using the joystick[
▶
],
and press [Near] button or use joystick to continue.
- Set {Error Message Display} for On / Off using the joystick [
▶
].
Refresh is a function that calibrates P/T/Z regularly.
- Using the joystick [>] to select on/off
- Using the joystick [>] to select time from 3 hours to 7 days every 3 hours.
- Press [Open] button or use joystick to save settings.
- Press [Close] button or use joystick to return to previous menu (Back).
* Note
:
{Calibration} is a function for correcting an error on the angle of Pan / Tilt automatically.
{Calibration} can be set for Manual/Auto. In Manual mode, if there is an error on the angle of the
dome, execute {Calibration} using the joystick
[
▶
].
Press [Near] button to continue calibration
or press [Far] button to cancel calibration.In Auto mode, when there is an error on the angle of
the dome, the dome is corrected automatically. The motor of the Pan / Tilt will adjust its angle
automatically. {Error Message Display} is a function for displaying an error message to let a user
know {Sensing error} on the monitor.
3.7 Preset Menu
▲
/
▼
: move joystick up and down for selecting an item.
◀
/
▶
: move joystick left and right for moving an item.
▶
/ [Open] / [Near]: move joystick right to select or save settings or go to edit pages.
▶
/ [Close] / [Far]: move joystick to cancel or to exit current menu (Back).
27
CALIBRATION SETUP
AUTO CAL : AUTO
ERROR MSG DISP : OFF
CALIBRATION
REFRESH MODE : OFF
REFRESH TIME :
SAVE : OPEN
BACK : CLOSE
CONTINUE?
YES : NEAR
NO : FAR
PRESET SETUP
NO. 001
: NOT USED
EDIT
:
TITLE
:
D TIME
:
CLEAR
SAVE : OPEN
BACK : CLOSE