2. Installation and Connection
2.4 Setting Dome Camera
The device can communicate with external switching device such as multiplexer or DVRs by
setting the Rotary switch and Dip switch. Refer to tables below for setting the dome camera ID
and protocol selection. Total length of the cable for communication should not exceed 1km.
2.4.1 Setting the address (ID) of dome camera
To prevent wrong operation and malfunction, each dome camera has a unique address (ID).
The default setting is 0[ID001].
The value of rotary switch is in hexadecimal.
ex) SW301 : A, SW302 : F
0xAF => ID175
* Check appendix sheet
Dome Camera ID Setting (Rotary Switch, SW301, SW302)
X16
X1
SW301
SW302
2.4.2 Setting the protocol of dome camera
Dome Camera Protocol Setting (Dip Switch, SW303)
No1
CVBS
Off
NTSC
On
PAL
No2
Protocol
Off
Pelco D / P
On
Pelco P / Others
Dome Camera Baud Rate Setting (Dip Switch, SW303)
No3
No4
Baud
Rate(bps)
Off
Off
2400
Off
On
4800
On
Off
9600
On
On
38400
Dome Camera Termination Setting Off / ON
(NO5, Dip Switch, SW303)
12
SW302
SW301
SW303