Thank you for purchasing this series UPS. 
This series UPS is an intelligent, single phase in single phase out, high frequency online 
UPS designed by our R&D team who is with years of designing experiences on UPS. 
With excellent electrical performance, perfect intelligent monitoring and network functions, 
smart appearance, complying with EMC and safety standards, The UPS meets the 
world’s advanced level. 
Read this manual carefully before installation 
This manual provides technical support to the operator of the equipment.   

 

 

 

 

Содержание UDC9101RTH

Страница 1: ...Uninterruptible Power Systems 1 2 3KVA Operation Manual 4256 1749 E...

Страница 2: ...ut high frequency online UPS designed by our R D team who is with years of designing experiences on UPS With excellent electrical performance perfect intelligent monitoring and network functions smart...

Страница 3: ...uide 3 2 Installation and setup 4 2 1 Unpack checking 4 2 2 Real panel view 4 2 3 LCD control panel 6 2 4 Setup the UPS 6 3 Operations 7 3 1 Button operation 7 3 2 LCD display 8 3 3 UPS setting 11 3 4...

Страница 4: ...nt The UPS system must be absolutely dry before being installed Please allow at least two hours for the UPS system to acclimate the environment Do not install the UPS system near water or in moist env...

Страница 5: ...voltage exists in the terminals of high capability capacitor such as BUS capacitors Only persons are adequately familiar with batteries and with the required precautionary measures may replace batter...

Страница 6: ...use 2 1Unpack checking Don t lean the UPS when moving it out from the packaging Check the appearance to see if the UPS is damaged or not during the transportation do not switch on the UPS if any dama...

Страница 7: ...C input 2 Network Fax Modem Surge Protection option 3 Input circuit breaker 4 EPO option 5 USB communication port option 6 RS 232 communication port 7 SNMP intelligent slot option 8 Output receptacles...

Страница 8: ...k b Suggest using AWG14 or 2 1mm2 power cords for 3KVA 200 208 220 230 240VAC models c Upon completion of the wiring configuration please check whether the wires are securely affixed d Put the small c...

Страница 9: ...on ON Button Turn on the UPS Press and hold ON button for at least 2 seconds to turn on the UPS Down key Press this button to display next selection in UPS setting mode Exit setting mode Press this bu...

Страница 10: ...ds to disable or enable the alarm system But it s not applied to the situations when warnings or errors occur Switch to UPS self test mode Press and hold this button for 2 seconds to enter UPS self te...

Страница 11: ...9 03 Output voltage 04 Load 05 Temperature EnvironmentTemperatu re 06 Firmware Version UPS model...

Страница 12: ...ional status and mode 08 Alarm Code Warming Message All alarm codes are present when abnormal behavior s occur s 09 The charging status can also be shown on the screen as below while the charger is on...

Страница 13: ...ages Item Settings Content Displayed 01 Mode setting Press Func button to change the setting ECO or NOR orCF Press UP button to select the previous setting Press DOWN button to select the next setting...

Страница 14: ...on to select the previous setting Press DOWN button to select the next setting 06 Bypass voltage upper limit setting Press Func button to change the setting The bypass voltage upper limit range is 230...

Страница 15: ...ble AC power to output The UPS will also charge the battery at online mode Inverter led light ECO mode Energy saving mode When the input voltage is within voltage regulation range UPS will bypass volt...

Страница 16: ...t 18 Soft start failed Beep continuously Fault LED lit 19 UPS Inside Over Temperature Twice per second Fault LED lit 20 Heatsink Over Temperature Twice per second Fault LED lit 26 Battery over voltage...

Страница 17: ...is overload Remove excess loads from UPS output Alarm code is shown as 29 and FAULT led light The UPS shut down automatically because short circuit occurs on the UPS output Check output wiring and if...

Страница 18: ...n addition to the features of a standard NetAgent Mini NetAgent II has the option to add Net Feeler Lite to detect temperature humidity smoke andsecurity sensors Thus making NetAgent II aversatile man...

Страница 19: ...ns definition of connecting terminal on the board Relaycard electrical parameter max Type Relaycardcontact Max Switched Voltage AC 120V DC 24V AC 120V DC 5 12V Max Switched Current AC 1A DC 1A AC 1A D...

Страница 20: ...ltage point 230 264 setting the high voltage point in LCD from 230Vac to 264Vac Default 264Vac Bypass low voltage point 170 220 setting the low voltage point in LCD from 170Vac to 220Vac Default 170Va...

Страница 21: ...fter 5 seconds when the utility is normal 130 UPS transfer to bypass immediately when the utility is normal Short Circuit Hold Whole System Overheat Line Mode Switch to Bypass Backup Mode Shut down UP...