MDX [en-US]
8
Avoid the use of mounting aids as much as possible. Should a mounting aid be required, use a commercially available
contact adhesive. The adhesive should only be applied at selected points (three to four spots) and in thin layers. Do
not use cyanoacryiate adhesives (quick-setting adhesives). If in certain cases mounting aids or anti-adhesives other
than those described are required, please contact the sealing material manufacturer.
The operator is responsible for ensuring that all maintenance inspection and installation work is carried out by
authorized, duly qualified staff who are thoroughly familiar with these operating instructions.
A regular maintenance schedule will help avoid expensive repairs and contribute to trouble-free, reliable operation of
the pump with a minimum of maintenance expenditure.
Repair and maintenance work to the pump must only be carried out by specially trained personnel, using original
equipment spare parts.
WARNING
Proper lifting, rigging and safety practices must be observed at all times. Do not attempt to lift heavy
components by hand as this may result in personal injury and damage to equipment.
Work on the unit must only be carried out with the electrical connections disconnected and locked out.
Make sure that the pump set cannot be switched on accidentally.
Pumps handling liquids posing health hazards must be decontaminated. When draining the medium
ensure there is no risk to persons or the environment. All relevant laws must be adhered to.
Before dismantling or reassembly, secure the pump so as to make sure it cannot be switched on
accidentally. The shut-off elements in the suction and discharge nozzles must be closed. The pump
must have cooled down to ambient temperature, drained, and its pressure must be released.
Before dismantling or reassembly of vertical cantilever pumps, remove the motor and pull the assembly
out of the sump.
Upon completion of the work, all safety-related and protective equipment must be properly refitted
and/or reactivated before starting the pump set.
Always ensure that lifting equipment does not bind the swivel hoist ring. Binding can cause the ring to
fail. When lifting a plate that contains two swivel hoist rings, do not allow the angle between the lines
of tension from the rings to exceed 120°. This could cause the hoist rings to fail.
Do NOT bind lifting equipment
Do NOT exceed 120° between lines of tension
120°