background image

9 Related documents 

9.1 Typical installation positions 

Etabloc G 
up to motor size 112 = 4 kW 

up to motor size 132 = 5.5 kW to

180 = 22 kW 

As-delivered condition

Horizontal installation, attachment below

up to motor size 112 = 4 kW 

For vertical installation with motor on top please contact KSB

Position of condensate holes    o = open

x = closed

Horizontal installation, attachment above

Motor has to be turned through 180º

Etabloc N

up to motor size 180 = 22 kW 

For vertical installation a vent valve must be fitted
to prevent dry running of the mechanical seal.

Etabloc

1165:21/4

1167:72

1167:22/5

1167:68

1167:69

to 180 = 22 kW

For vertical installation a vent valve must be fitted
to prevent dry running of the mechanical seal

14

Содержание Etabloc

Страница 1: ...Operating Instructions Close coupled Pumps Etabloc...

Страница 2: ......

Страница 3: ...tart up shutdown 8 6 1 Commissioning 8 6 1 1 Shaft seal 8 6 1 2 Priming the pump and checks to be carried out 8 6 1 3 Final check 8 6 1 4 Contact guard 8 6 1 5 Start up 8 6 1 6 Shutdown 8 6 2 Operatin...

Страница 4: ...tabloc N 7 5 3 11 Noise characteristics 4 4 6 Non compliance with safety instructions 2 3 4 Operating limits 6 2 9 Ordering spare parts 7 6 1 12 Personnel qualification and training 2 2 4 Place of ins...

Страница 5: ...in a perfectly legi ble condition at all times 2 2 Personnel qualification and training All personnel involved in the operation maintenance inspec tion and installation of the unit must be fully qual...

Страница 6: ...rt foot Fig 3 1 2 Transport of the unit with motor pump foot During transport the shaft 210 of the pump without motor must be locked in place 1 Press cover plates 68 3 slightly together and remove fro...

Страница 7: ...ved and complied with The test certificate supplied must be kept close to the loca tion of operation for easy access e g foreman s office 5 2 Checks to be carried out prior to installation All structu...

Страница 8: ...der to avoid excessive pressure loss across the strainer due to clogging Conical strainers with laid in wire mesh having a mesh width of 0 5 mm and a wire diameter of 0 25 mm of corrosion resistant ma...

Страница 9: ...been properly connected 6 1 1 Shaft seal Shaft seal see sections 7 4 4 and 7 5 2 6 1 2 Priming the pump and checks to be carried out Before start up the pump and the suction line must be vented and pr...

Страница 10: ...t is advisable to close the pump nozzles e g with plastic caps or similar 6 4 Returning to service after storage Before returning the pump to service carry out all checks and maintenance work specifie...

Страница 11: ...and reassembly must always be carried out in accordance with the relevant exploded view 7 4 1 Fundamental instructions and recommendations Repair and maintenance work to the pump must only be car rie...

Страница 12: ...t sequence 7 5 2 Mechanical seal Reassembly is effected in reverse order to dismantling The following rules must be observed when fitting a mechan ical seal Extreme care and cleanliness The protective...

Страница 13: ...umber of pumps including stand by pumps 2 3 4 5 6 and 7 8 and 9 10 and more Part No Description Quantity of spare parts 210 Shaft 1 1 1 1 2 2 2 20 230 Impeller including casing wear ring 502 2 2 1 1 1...

Страница 14: ...shaft sleeve Fit new shaft seal D Vibrations during pump operation Improve suction conditions Increase pressure at the pump suction nozzle D D D Pump is warped Check pipeline connections and secure fi...

Страница 15: ...tor on top please contact KSB Position of condensate holes o open x closed Horizontal installation attachment above Motor has to be turned through 180 Etabloc N up to motor size 180 22 kW For vertical...

Страница 16: ...abyrinth seal 433 Mechanical seal 502 1 2 Casing wear ring Part No Description 523 Shaft sleeve 550 1 1 Disc 802 Motor for close coupling 902 1 2 4 2 Stud 903 1 Screwed plug 920 1 3 Hex nut 920 4 2 He...

Страница 17: ...Shaft sleeve 550 1 1 Disc 802 Motor for close coupling 902 3 42 Stud 903 1 Screwed plug 920 1 4 Hex nut 930 Spring washer 940 Key Auxiliary connections 1M Pressure gauge 6B Casing drain 6D Priming an...

Страница 18: ...163 Discharge cover 210 Shaft 230 Impeller 341 Drive lantern 400 1 Gasket 411 5 Joint ring 433 Mechanical seal Part No Description 801 Flanged motor 902 1 3 4 5 Stud 903 1 2 Screwed plug 920 1 4 5 He...

Страница 19: ......

Страница 20: ...Etabloc Gartone Press Tel 011 440 6126 29 6 2004 Subject to technical modification without prior notice...