5.3.1.7 Installing the pump set
NOTE
For pumping water containing sludge and suspended solids pump sets with impeller type
S (cutter) are preferable. In such cases it is recommended to use an inclined claw.
NOTE
Make sure the pump set with the pre-assembled claw can easily be slipped over the
mounting bracket, threaded onto the guide rails and lowered down. If required, alter the
position of the crane during installation.
1. Guide the pump set over the suspension bracket/mounting bracket, thread it
onto the guide wires/rails and slowly lower it down.
The pump set attaches itself to duckfoot bend 72-1.
2. Attach the lifting chain/rope to hook 59-18 at the mounting bracket.
5.3.2 Transportable wet installation
Before installing the pump set, fit the 3 pump feet and foot plate, if applicable.
Fitting the pump feet
1. Undo screws 914.03.
2. Push pump feet 182 into the opening in the suction cover.
3. Tighten screws 914.03 again to the indicated tightening torque. (
Fitting the foot plate
1. Fit the foot plate to the three pump feet with screws, discs and nuts. Observe the
Attaching the lifting chain/rope
1. Attach the lifting chain or rope to the shackle on the discharge nozzle side (see
drawing and table "Types of attachment").
Connecting the piping
The DIN connection can be connected to rigid or flexible pipes.
Fig. 17: Connection options
UG1274785
Fig. 16: Attaching the
lifting chain/rope
5 Installation at Site
26 of 66
Amarex® N
Goodnal STP ST041 Biological Treatment (KSB WAS PUMP 1 & 2 PU-0530-010 OM Instructions) Vendor Manual
Q-Pulse Id VM381
Active 29/10/2013