Fitting the guide rails (arrangement with 1 guide rail)
1. Position rail 710 (for DN 50 - DN 65) into the recess of duckfoot bend 72.1 or (for
DN 80 - DN 100) on the conical boss. Place the rail in vertical position.
2. Mark the length of rail 710 (up to the lower edge of the mounting bracket),
taking into account the adjusting range of the slotted holes in mounting bracket
894.
3. Shorten rail 710 with a 90° cut to the pipe axis. Debur the rail inside and outside.
4. Insert mounting bracket 894 into guide rail 710 until the mounting bracket rests
on the rail end.
5.3.1.5 Fitting the guide hoop arrangement (for DN 50 and DN 65 only)
1. Insert the ends of guide hoop 571 into the grooves of duckfoot bend 72.1.
2. Fasten the flanged duckfoot bend to the tank/sump floor with 2 anchor bolts
5.3.1.6 Preparing the pump set
Fastening the claw for guide wire, single guide rail and guide hoop
arrangement
1. Fasten claw 723 with screw 914.05 and disc 550.35 to the discharge flange (see
drawing). Tighten the screw to a torque of 17 Nm.
710
894
60.3
33.7
UG1273704
Fig. 12: Fitting 1 guide rail
571
UG1274642
72.1
90-3.38
Fig. 13: Fitting the guide
hoop arrangement
2563:103
732
550.35
914.05
17 Nm
Fig. 14: Fastening the
claw for guide wire, single
guide rail and guide hoop
arrangement