Fastening the claw for guide rail arrangements with 2 guide rails
1. Fasten claw 732 with screws 920 and discs 550 to the discharge flange (see
illustration). Tighten the screw to a torque of 70 Nm.
2. Fit profile joint 410 in the groove of the claw.
This will seal the duckfoot bend / pump connection.
Attaching the lifting chain/rope
UG1274774
Attaching the lifting
chain/rope - stationary
wet installation
Stationary wet installation
1. Attach the lifting chain or rope to the lug/eyebolt/bail at the pump set on the
opposite side of the discharge nozzle.
This attachment point achieves a forward inclination of the pump set towards the
discharge nozzle, which allows the claw to hook onto the duckfoot bend.
UG1274785
Attaching the lifting
chain/rope - transportable
wet installation
Transportable wet installation
1. Attach the lifting chain or rope to the lug/eyebolt/bail at the pump set on the side
of the discharge nozzle.
This attachment point achieves a forward inclination of the pump set towards the
discharge nozzle, which allows the pump claw to hook onto the duckfoot bend.
Table 13: Types of attachment
Drawing
Type of attachment
59-18
885
59-17
UG1274869
Shackle with chain at the pump casing
59-17
Shackle
59-18
Hook
885
Chain
59-18
885
59-17
576
UG1274897
Shackle with chain at the pump handle
59-17
Shackle
59-18
Hook
576
Pump handle
885
Chain
Fig. 15: Fastening the
claw for guide rail
arrangements with 2
guide rails
5 Installation at Site
Amarex® N
25 of 66
Goodnal STP ST041 Biological Treatment (KSB WAS PUMP 1 & 2 PU-0530-010 OM Instructions) Vendor Manual
Q-Pulse Id VM381
Active 29/10/2013
Page 27 of 76