Titan 45-1
Titan 45-2
Manually operated drain valve
Application:
The drain valve is used to deaerate and drain the
compressed air reservoir.
Servicing:
The valve should be operated daily in winter, otherwise
weekly or after 20 operating hours.
If the valve leaks due to contamination it must be
screwed out of the compressed air reservoir and
cleaned or replaced.
3) Compressed air reservoir
The compressed air reservoir stores the compressed
air provided by the compressor. During operation
condensate (water) can collect in the compressed air
reservoir.
The drain valve at the base of the compressed air
reservoir should be operated daily in winter, otherwise
weekly or after 20 operating hours. If the reservoir is
damaged it must be replaced.
Check:
Drain compressed air reservoir. Check drain valves for
leaks.
Check pressure drop in compressed air reservoir per
full braking with tightly set brakes. Permissible pressure
drop per full braking max. 0.7 bar.