3
INSTALLATION
22
WATERFLUX 3070
www.krohne.com
06/2016 - 4004999701 - MA WATERFLUX 3070 - R01 en
3.7 Mounting
3.7.1 Torques and pressures
The maximum pressure and torque values for the flowmeter are theoretical and calculated for
optimum conditions and use with carbon steel flanges.
Tightening of bolts
•
Always tighten the bolts uniformly and in diagonally opposite sequence.
•
Do not exceed the maximum torque value.
•
Step 1: Apply approx. 50% of max. torque given in table.
•
Step 2: Apply approx. 80% of max. torque given in table.
•
Step 3: Apply 100% of max. torque given in table.
Figure 3-17: Tightening of bolts