3
ELECTRICAL CONNECTIONS
28
POWERFLEX 2200 C/F/S/D
www.krohne.com
07/2016 - 4005318901 - QS POWERFLEX 2200 R01 en
3.1 Electrical installation: 2-wire, loop-powered
3.1.1 Compact version
1
Loosen the lock screw with a 2.5 mm Allen wrench.
2
Turn the cover counterclockwise with a strap wrench.
3
Remove the cover.
Terminals for electrical installation
Figure 3-1: Terminals for electrical installation
1
Grounding terminal in the housing (if the electrical cable is shielded)
2
Current output -
3
Current
4
Location of the external grounding terminal (at the bottom of the converter)
INFORMATION!
Electrical power to the output terminal energizes the device. The output terminal is also used for
HART
®
communication.
CAUTION!
•
Use the applicable electrical cables with the cable glands.
•
Make sure that the current is not more than 5 A or that there is 5 A-rated fuse in the
electrical circuit that energizes the device.
Open the terminal compartment cover
Figure 3-2: How to open the terminal compartment cover