3.9 Technical Data
H
Ha
arrd
dw
wa
arre
e
S
So
offttw
wa
arre
e
Physical
PROFIBUS MBP Interface
according to IEC 61158
GSD
GSD file can be downloaded from the
KROHNE Homepage
http://www.krohne.com
Connection
Independent of polarity
Device profile
PA Profile compact class B, V3.01
Base current 10,5 mA
Address range
0...126; default 126
0 to 125 via “set_slave_add”
0 to 126 via “Local Display”
126 via “FACTORY_RESET = 2712”
FDE
yes: separate fault discon-
nection electronics provided
Local control
local display and operator interface at
device.
Fault
current
6 mA; (fault current = max.
continuous current – base
current).
SAPs
2 MS1 SAPs - acyclic interface to PLC
3 MS2 SAPs - the number of MS2 Service
Access Points is typically equal to the
maximum number of master class 2 tools
Starting
current
< 12mA
Function Blocks
1 PB
1 TB
8 AI
3 TOT
“Ex“
approval
EEx ia IIC or EEx ib IIC/IIB,
FISCO device(for details see
“MFC 300 (OPTIMASS)
Handbook”)