Rev. Date: 12/14/10
Page 16
MODEL #5200-P
6. When operating in
Remote mode
, the 4-Position Selector Switch must be set to
Remote
position. (See illustration 5 on page 15.)
7. Remote control hand pendant positions will be selected from the following:
BLOWER-FEED
- operates both
blower
and
agitator-feed
simultaneously
OFF
- (middle position) all functions stop
BLOWER
- operates the
blower
only
8. Use the Auxiliary Outlet on the Main Control Panel for supplying
continuous
power (while
red
Main
Disconnect Switch is ON) to accessories.
Stopping Your Machine:
1) Switch the Remote Switch to “AIR ONLY” and wait until the hose is clear of all material.
2) Turn the Control Switch on the remote control cord to the OFF position.
3) Turn the Main Disconnect Switch to the OFF position.
4) Disengage the PTO.
SAFETY NOTE:
DO NOT FILL THE HOPPER TO CAPACITY AT THE END OF THE DAY. THE MATERIAL
WILL COMPRESS AND CAN CAUSE MACHINE LOCKUP DURING THE NEXT START-UP.
Mechanical Settings:
The controls of your machine contain the blower and slidegate controls to adjust your machine for
each application and type of fiber. (See illustration 7 on page 17.)
Blower control
(air) and
slidegate
(material feed) are adjusted according to:
TYPE OF MATERIAL:
Cellulose and fiberglass have different textures and densities that
respond to machine settings.
HOSE:
Corrugations or roughness of interior surface, diameter, length and
elevation of hose will also require varying adjustments.
WEATHER CONDITIONS: Temperature and humidity may require day to day adjustment of
machine settings.
Blower Control and Slidegate General Settings:
Blower control can increase or decrease the amount of air in the system, affecting the velocity
(speed) and spread rate (coverage) of fiber. (See illustration 7 on page 17.) The blower control valve
is used for controlling air pressure and amount of air flow.
Opening or closing slidegate (material feed) controls the amount of fiber dropping into the airlock
which changes the production rate (lbs. per hour). (See illustration 7 on page 17.) For calibration
purposes the scale located on the machine indicates how many inches the airlock slidegate is opened.
Содержание 5200-P
Страница 28: ...Rev Date 12 14 10 Page25 MODEL 5200 P PARTS LIST 5200 Exploded Parts View Unidirectional Center Down ...
Страница 29: ...Rev Date 12 14 10 Page26 MODEL 5200 P 5200 Exploded Parts View ...
Страница 30: ...Rev Date 12 14 10 Page27 MODEL 5200 P 5200 Exploded Parts View ...
Страница 36: ...Rev Date 12 14 10 Page33 MODEL 5200 P SERVICE RECORD DATE MAINTENANCE PERFORMED COMPONENTS REQUIRED ...