KREMLIN
Page 5
Manual : 573.049.112
INSTALLATION INSTRUCTIONS
A -
B -
1 -
2 -
Explosive area
area 1 (Z1)
or area 2 (Z2) :
spray booth
Non explosive
area
Pump
Spray gun
5. OPERATING
PRINCIPLE
The motor is coupled to the hydraulic section piston. When the piston is raising and lowering the material
is siphoned and dispensed simultaneously.
The elevator (2) supports the pump. It includes 2 double action jacks (25) and (26).
When air pressure is applied on (15) (level 14 in a bottom position), the pressure force is exerted
downwards and the pump is going down.
When air pressure is applied on (16) (level 14 in a top position), the pressure force is exerted upwards
and the pump is raising.