background image

2  If the inlet water pipe is 6mm, should ensure that the inlet water tube and connector have 30-40cm

of straight piping to avoid burst pipe accidents caused by bending in the pipe.

3  If the power cord wiring needs to be longer, then according to the wiring requirements use a Φ8mm

pinched tube to wrap around the connection, then on the outside wrap around insulating electrical
tape, do not place it on the floor, it should be suspended in the air or in another place away from the
ground.

4

When installing, if you need to make a hole in the wall, you should first make sure that there are no
electricity or water lines in the location you plan to drill.

5

The   machine   must   be   connected   with  the   switch   with  reliable   grounding   line   ,   otherwise

manufacturers are not responsible for safety accidents caused.

6

The switch power supply must  switching power supply must put  in ventilated  and  waterproof

place

 and keep adequate distance with machine, in avoid of accidents caused by water input.

Testing Methods

After confirming that the water route connections are correct,
confirm that you have a power supply and/or water supply.  Then
follow these steps to troubleshoot the machine:

      

Diagram 1

 

 1

1. Open the tap water inlet valve as well as the water purifier inlet water ball valve, plug in the power

source (See Diagram 11), water will start to drain through the discharge outlet.

2. Wait for the water purifier to operate stably (about 5-10 seconds), check each connection to make sure

it is secure, see if there is any leakage from the membrane shells, filters, etc.

3. Close the pure water gooseneck faucet and storage tank ball valve, wait approximately 30 seconds,

check whether or not the water purifier waste water has stopped.

4. Open the gooseneck faucet, observe whether pure water is flowing through the faucet, if no pure water

is flowing, check whether the tap water pressure is too low or whether the high pressure switch cannot
be reset.

5. Wait until the machine is operating, close the inlet water ball valve, after a short time observe whether it

has stopped operating, if it has stopped operating, check whether the low-voltage switch can be reset.

6.   Wait some time to make sure everything is correct, then the water purifier can be used safely.
7. Check the water quantity, which go to drain. It's should be according with the table 4.1

If the quantity of water is less than the information above it could
lead to quick failure of the membranes.

8.  Check   the   TDS   after   some   litters   of   water   pass   through   the

gooseneck faucet. If the the membranes rejection is not very big,
please take out every membrane from the membrane shell and
insert it again with clockwise and anticlockwise rotations. Check it
again.

Note:  The  pure  water  TDS  could  be  higher   after   coconut   activated
post carbon filter till moment, when the unwanted active carbon go
out.

-16-

Содержание NEW LINE A

Страница 1: ...ter that can be consumed directly so the water you drink is cleaner and also beneficial to your health Before you install and use this water purifier please be sure to read the user manual this enable...

Страница 2: ...Installation Preparations 12 2 Instructions for Proper Installation 13 3 Installation Notes 13 Testing Methods 16 Usage Methods 17 Maintenance and Upkeep 17 1 Filter Replacement Time 17 2 Filter Repla...

Страница 3: ...not put heavy objects on the water purifier If heavy objects are placed on the water purifier it may result in damage to the water purifier s dust cover or internal components which could lead to leak...

Страница 4: ...waste water ratio device are clogged it may lead to high TDS effluent the RO membrane may get blocked or the water purifier may not work Water purifier inlet water temperature should not exceed 38 If...

Страница 5: ...ed disassembly or modification of the machine could lead to machine malfunctions and leakage accidents For example the system s pump type D cannot be installed on the system model A B or C In this cas...

Страница 6: ...ction 1 Blown up profile of the water purifier The system could be in 2 versions based on normal bracket or stable bracket Normal Bracket Stable Bracket with Pressure meter Diagram 1 2 Electrical diag...

Страница 7: ...s per day Model NAME NEW LINE A NEW LINE A NEW LINE B NEW LINE B NEW LINE C NEW LINE C NEW LINE D NEW LINE D Voltage AC 220 240 V 50HZ 24V 1 8A AC 220 240 V 50HZ 24V 2 2A AC 220 240 V 50HZ 36V 1 5A AC...

Страница 8: ...ype II Type II Hardness level max mg ekv lit 8 8 8 8 8 8 8 8 MAX pure water flow per day Lit 40 40 40 40 80 80 120 140 120 140 Notes Due to product improvements the above parameters may change but the...

Страница 9: ...e RO membrane Flow Restrictor Waste Water Ratio Device controls waste water flow Low Voltage Switch To prevent pump idling When the inlet water pressure is less than 0 03 MPa or when the inlet water s...

Страница 10: ...ately after long work period of time The limit time of flashing could be between 0 5 1 5 min the light is on when the drinking goose neck faucet closed The light is on when the machine purify the wate...

Страница 11: ...close machine will flush membrane 30 seconds The pump and inlet solenoid and flush solenoid are all off The buzzer will beep 10 times Full Function 1 If the high pressure switch is open and the machi...

Страница 12: ...same time the machine is producing water This design solves the contamination problem such as odours bacteria etc caused by long time pure water storage in tank It supplies the real pure and fresh wa...

Страница 13: ...box wrap one end of the ball valve external threads with the appropriate Teflon tape See Diagram 5 if you have silica gel spread a little on and then screw the ball valve into the corresponding hole...

Страница 14: ...Take the first RO membrane from its packaging put the end of the membrane with the O ring into the reverse osmosis membrane shell See Diagram 9 and push it in finally screw the membrane shell cover ba...

Страница 15: ...brane components the membrane manufacturer does not assume responsibility for returned components due to damage during installation Damage to the membrane shell and reverse osmosis membrane element ca...

Страница 16: ...ter will start to drain through the discharge outlet 2 Wait for the water purifier to operate stably about 5 10 seconds check each connection to make sure it is secure see if there is any leakage from...

Страница 17: ...ty and utilisation rate and the average indicators there will be more obvious differences between the filter s actual use time and the estimated cycle such as premature filter clogging premature failu...

Страница 18: ...ce the filter inside the filter cartridge use the wrench to tighten the filter cover For replacement of membrane elements please see RO Membrane Installation Page 8 3 Notes RO membrane water productio...

Страница 19: ...easure the output voltage replace The high pressure pump is working properly but no water is being produced High pressure pump has lost pressure Measure the water pump pressure replace Inlet water sol...

Страница 20: ...s the final explanation rights if this manual is unclear has mistakes or if there were printing problems which caused problems Packing List Main machine including 2 units of RO membranes 1 unit Water...

Отзывы: