VP-771 - The VP-771 RS-232 Communication Protocol
69
69
1st
Level
2nd Level
3rd Level
4th Level
Range
Func. Note
1280x1024@60
60
1280x1024@75
61
1280x960@85
62
1920x1200@60RB
63
1280x1024@85
64
1600x1200@60
65
1680x1050@60
66
NONE
0XF5 or 0XFF
Window Control
Main Win
0
721
When in the single
window mode, only
Main Win is valid
PiP Win
1
H Position
0:2047
722
The value range is
dynamic, FW
prevents exceeding
of boundaries
V Position
0:2047
723
Transparency
ON
1
724
OFF
0
Transparency Gain
0.1:1.6
725
Transparency Bias
-400:400
726
Blink
ON
1
727
OFF
0
Blink Period
0.1:1.6
728
Timeout
Off
0
729
30 Sec
1
60 Sec
2
Advanced
V Keystone
-400:400
731
In the OSD menu
the value range
shows -80:80.
Unavailable for
interlaced output
Auto Sync Off
On
1
732
Two idle minutes
are required to
trigger screen
shutdown
Off
0
Luma Keying
On
1
733
Volatile parameter.
Screen may flicker.
Keying the PiP
window
Off
0
Pause
Freeze
On
1
741
Off
0
Blank
On
1
742
Off
0
Mute
On
1
743
Off
0
Disable Outputs
On
1
744
Off
0
Protocol
P3K
0
750
Legacy
1
Содержание VP-771
Страница 1: ...KRAMER ELECTRONICS LTD USER MANUAL MODEL VP 771 Presentation Switcher Scaler P N 2900 300096 Rev 3...
Страница 2: ......
Страница 3: ......
Страница 19: ...14 VP 771 Connecting the VP 771 Figure 3 Connecting the VP 771 Presentation Switcher Scaler...
Страница 76: ......