VP-771 - The VP-771 RS-232 Communication Protocol
61
61
Read protocol
Ethernet port
ETH-PORT?
PROTOCOL
ETHP?
ETH-PORT
PROTOCOL
,
PORT
PROTOCOL
= TCP / UDP
(transport layer protocol)
PORT
=
Ethernet port to enter protocol 3000 commands.
1-65535 = User defined port
0 - reset port to factory default (50000 for UDP, 5000 for TCP)
Load new
peripheral
firmware P
Step 1:
LDFW
SIZE
Response 1:
READY
or
LDFW
SIZE
ERR###
Step 2: If
ready
was received, send
FIRMWARE_DATA
P
Response 2:
LDFW
SIZE
RESULT
Load new video
core firmware
Step 1:
LDFWS
SIZE
Response 1:
READY
or
LDFWS
SIZE
ERR###
Step 2: If
ready
was received, send
FIRMWARE_DATA
P
Response 2:
LDFWS
SIZE
RESULT
Load new
audio/graphic
memory file.
Step 1:
LDMFS
SIZE
Response 1:
READY
or
LDMFS
SIZE
ERR###
Step 2: If
ready
was received, send
FIRMWARE_DATA
P
Response 2:
LDMFS
SIZE
RESULT
11.2 Audio/Video Communication Protocol
The audio/video protocol commands defines all the function numbers, their valid
parameters can be used with protocol 3000 or the Legacy protocol.
Using the Communication Protocol with Protocol 3000 (the “Y” Command)
Set
Command
:
Type in: “Y Control_Type=0,Function,Param”
Reply: “~id=01Y Control_Type=0,Function,Param OK”
Set command example, set window control (721) to PiP:
Send: “#y 0,721,1”
Reply: “~01@Y 0,721,1 OK”
Get Command:
Type in: “Y Control_Type=1,Function”
Result: “~id=01Y Control_Type=1,Function,Param”
Get command example: get window control setup (721):
Send: “#y 1,721”
Result: “~01@y 1,721,1”