62
VP-771 - The VP-771 RS-232 Communication Protocol
You can add a
last parameter
, to be located fourth in SET or third
in GET, to define a specific window.
For example:
Set H Sharpness value to 10 on the PiP window (
1
): “#y 0,510,10,
1
”
Get H sharpness of the Main window (
0
): “#y 1,510,
0
”
Using the Communication Protocol with Legacy Protocol
Set Command:
Type in: Y
Control_Type
Function
Param[CR]
Reply: Z
Control_Type
Function
Param[CR][LF]
Get Command:
Type in: Y
Control_Type
Function[CR]
Reply: Z
Control_Type
Function
Param[CR][LF]
When sending a command, a blank character may precede [CR] if desired
Example
:
Example 1: set brightness value as 32
Send: Y
0
410
32[CR]
Reply: Z
1
410
32[CR][LF]
Example 2: get current output resolution. (4 = SVGA)
Send: Y
1
631[CR]
Reply: Z
1
631
4[CR][LF]