VP-733 - VP-733 Communication Protocol
Set
Get
Function
Parameter1
Description Control Type
0
1
306
384~2047
Advanced: Input Mode: VT (temp value, unless to run
the Input mode save)
0
1
307
2~(HS-13)
Advanced: Input Mode: VW (temp value, unless to run
the Input mode save)
0
1
308
15~(VT-VA-1)
Advanced: Input Mode: VS (temp value, unless to run
the Input mode save)
0
1
309
480~1200
<= (VT-16)
Advanced: Input Mode: VA (temp value, unless to run
the Input mode save)
0
1
310
0: Negative polarity
1: Positive polarity
Advanced: Input Mode: VP (temp value, unless to run
the Input mode save)
0
1
311
25000 < OCLK <= 297000
Advanced: Input Mode: OCLK
Temp value, unless to run the Input mode save
The three bytes of high byte is integer; the three bytes
of low byte is
the decimal place.
The unit is KHz
0
1
312
0: Off
1: On
Advanced: Input Mode: Enable
0
-
313
N/A
Advanced: Input Mode: Save
0
1
320
0: Custom1
1: Custom2
2: Custom3
3: Custom4
Advanced: Output Mode: Custom Output
0
1
321
512~3071
Advanced: Output Mode: HT (temp value, unless to run
the Output mode save)
0
1
322
32~(HS-48)
Advanced: Output Mode: HW (temp value, unless to
run the Output mode save)
0
1
323
80~(HT-HA-12)
Advanced: Output Mode: HS (temp value, unless to run
the Output mode save)
0
1
324
640~1920
<= (HT-92)
Advanced: Output Mode: HA (temp value, unless to run
the Output mode save)
0
1
325
0: Negative polarity
1: Positive polarity
Advanced: Output Mode: HP (temp value, unless to run
the Output mode save)
0
1
326
384~2047
Advanced: Output Mode: VT (temp value, unless to run
the Output mode save)
0
1
327
2~(HS-13)
Advanced: Output Mode: VW (temp value, unless to
run the Output mode save)
0
1
328
15~(VT-VA-1)
Advanced: Output Mode: VS (temp value, unless to run
the Output mode save)
0
1
329
480~1200
<= (VT-16)
Advanced: Output Mode: VA (temp value, unless to run
the Output mode save)
0
1
330
0: Negative polarity
1: Positive polarity
Advanced: Output Mode: VP (temp value, unless to run
the Output mode save)
0
1
331
25000 < OCLK <= 297000
Advanced: Output Mode: OCLK
Temp value, unless to run the Output mode save
The three bytes of high byte is integer; the three bytes
of low byte is the decimal place.
The unit is KHz
0
-
332
N/A
Advanced: Output Mode: Save
0
-
333
N/A
Advanced: Output Mode: Set Current (temp value,
unless to run the Output mode save)
0
-
334
N/A
Advanced: Output Mode: Read HDMI1 EDID
0
-
335
N/A
Advanced: Output Mode: Read HDMI2 EDID
0
-
336
N/A
Advanced: Output Mode: Read DP EDID
0
-
337
N/A
Advanced: Output Mode: Read VGA EDID