background image

Kramer Electronics Ltd. 

 

VM

4HDT

VM

3HDT

VM

2HDT 

 

– Introduction 

 

 

Feature 

Function 

 

PROGRAM Mini USB 
Connector

 

Use to send RS-232 Commands (see 

Kramer Protocol 3000 

Commands

 on page 

19

). 

Connect to a PC to perform firmware upgrades (via K-Upload) 
and work with the EDID Designer. 
K-Upload and EDID Designer can be downloaded from our Web 
site at: 

www.kramerav.com/manual/VM-4HDT

.

 

To use the mini USB port, you need to download and the Kramer 
USB driver from our Web site at: 

www.kramerav.com/support/product_downloads.asp

 and install it. 

 

EDID SETUP Button 

Press to acquire the EDID from an output or select the default 
EDID (see 

Acquiring an EDID

 on page 

12

)

 

IN LED 

Lights when an active input signal is detected. 

 

LINK LEDs 

Lights when a link is established with the receiver.  

 

OUTPUT LEDs 

Lights when an active output acceptor is detected. 

 

ON LED 

Lights when the unit receives power. 

 

INPUT HDMI

 

Connector 

Connects to the HDMI source 

 

LOOP OUT HDMI Connector 
(for 

VM

2HDT

 and 

VM

3HDT

Connect to a local monitor or a daisy-chained DA, for example, 

VM

4HDT

 

HDBT OUT Connectors 

Connect to an HDBT acceptor, for example 

TP-580R

 

IR 3.5mm Mini Jack 

Connect an IR sensor for sending IR signals to a remote device 
(for example, a projector connected to an HDBT receiver). 

Or 

Connect an IR emitter (attached to a local device) for receiving IR 
signals from the device’s IR remote control via HDBT. 

 

RS-232 3-pin Terminal Block

 

Connect to a serial controller to control a remote device that is 
connected to the RS-232 port of an HDbaseT receiver. 

Or

 

Connect to a local device which is to be controlled by an RS-232 
controller connected via HDBT. 

 

SETUP 8-way DIP-switch

 

Used to set the IR and RS-232 commands behavior, (see 

Setting 

the DIP-Switches

 on page 

9)

 

SETUP 4-way DIP-switch

 

Always keep all four DIP-switches UP (off). 

 

5V DC Connector 

Connects to the 5V DC power supply. 

 

Содержание VM-4HDT

Страница 1: ...P N 2900 300486 Rev 4 www kramerAV com USER MANUAL MODELS VM 4HDT 1 4 HDMI to HDBT DA VM 3HDT 1 3 HDBT DA Extender VM 2HDT 1 2 HDBT DA Extender...

Страница 2: ...ons 3 Defining the HDMI to HDBT DA 4 Connecting the VM 4HDT VM 3HDT and VM 2HDT 6 HDBT RJ 45 Pinout 8 Operating the VM 4HDT VM 3HDT and VM 2HDT 9 IR and RS 232 Signal Routing 9 EDID Configuration 11 F...

Страница 3: ...inal box and packaging materials for possible future shipment Review the contents of this user manual Go to www kramerav com downloads VM 4HDT to check for up to date user manuals application programs...

Страница 4: ...mer HDMI to HDBT DA VM 4HDT is a high quality long reach HDBaseT extender and distributor that takes HDMI IR and RS 232 signals and converts and distributes them to 4 HDBaseT outputs The VM 4HDT suppo...

Страница 5: ...llation Twisted pair cables for HDBaseT signals wiring Compact Mega TOOLS fan less enclosure for over ceiling mounting or side by side rack mounting Installing your VM 4HDT Install VM 4HDT using one o...

Страница 6: ...T Introduction 4 Defining the HDMI to HDBT DA Figure 1 defines the VM 4HDT Figure 1 VM 4HDT 1 4 HDMI to HDBT DA Figure 2 defines the VM 3HDT Figure 2 VM 3HDT 1 3 HDBT DA Extender Figure 3 defines the...

Страница 7: ...etected ON LED Lights when the unit receives power INPUT HDMI Connector Connects to the HDMI source LOOP OUT HDMI Connector for VM 2HDT and VM 3HDT Connect to a local monitor or a daisy chained DA for...

Страница 8: ...source it will output an HDCP secured signal that will not passed through to any connected non HDCP acceptors 3 For VM 3HDT and VM 2HDT only connect the LOOP HDMI connector to an HDMI acceptor for exa...

Страница 9: ...Kramer Electronics Ltd VM 4HDT VM 3HDT VM 2HDT Connecting the VM 4HDT VM 3HDT and VM 2HDT 7 Figure 4 Connecting the VM 4HDT Figure 5 Connecting the VM 3HDT VM 2HDT...

Страница 10: ...e recommend that for HDBT cables the ground shielding be connected soldered to the connector shield For optimum range and performance use the recommended Kramer cables available at www kramerav com pr...

Страница 11: ...output ports Each signal can pass commands from the VM 4HDT to a single output several outputs or all of the outputs or the other way around from the output s to the VM 4HDT The IR RS 232 signal rout...

Страница 12: ...r to IR Sensor Projector IR signal Routing To route the IR signal you have to use the Kramer external IR sensor on one end and the Kramer IR emitter cable on the other end In this example an IR emitte...

Страница 13: ...on TP 580R 1 and TP 580R 2 not shown in Figure 9 they can also receive specific control commands each which will be ignored by devices of a different model Figure 9 IR RS 232 Routing Example EDID Conf...

Страница 14: ...ID Stop pressing EDID SETUP once the required EDID source is reached 4 Wait a few seconds until VM 4HDT acquires the EDID When complete all output LEDS return to normal operation displaying the presen...

Страница 15: ...ed EDID is then forced to support the RGB color space only Return to the normal EDID mode Press and hold the EDID button for few seconds until the output LEDs flash together once Continue to acquire t...

Страница 16: ...1 4 and HDBaseT 1 0 Control Front Panel EDID SETUP button IN LINK OUTPUT and ON indication LEDs Rear Panel DIP switches Power Consumption VM 4HDT 5V DC 3 2A VM 3HDT 5V DC 2 1A VM 2HDT 5V DC 1 6A Sour...

Страница 17: ...pported GTF standard Not supported Additional descriptors None Preferred timing Yes Native preferred timing 1280x720p at 60Hz 16 9 Modeline 1280x720 74 250 1280 1390 1430 1650 720 725 730 750 hsync vs...

Страница 18: ...epths at 32 44 48 kHz CE vendor specific data VSDB IEEE registration number 0x000C03 CEC physical address 1 0 0 0 Maximum TMDS clock 165MHz CE speaker allocation data Channel configuration 2 0 Front l...

Страница 19: ...framing of the command varies according to the terminal communication software K Touch Builder Kramer software K Config Kramer configuration software All the examples provided in this section are bas...

Страница 20: ...th a message closing character A string can contain more than one command Commands are separated by a pipe character Message starting character For host command query For device response Device addres...

Страница 21: ...addressing Start Address Body Delimiter Device_id Command_1 Parameter1_1 Parameter1_2 Command_2 Parameter2_1 Parameter2_2 Command_3 Parameter3_1 Parameter3_2 CR Device Message Format Start Address op...

Страница 22: ...Example 0x0D BUILD DATE Function Permission Transparency Set Get BUILD DATE End User Public Description Syntax Set Get device build date BUILD DATECR Get Response nn BUILD DATESPdateSPtimeCR LF Parame...

Страница 23: ...of chosen stage For the input 1 Input for the outputs for VM 4HDT 1 Output 1 2 Output 2 3 Output 3 4 Output 4 for VM 3HDT and VM 2HDT 1 Loop Output 2 Output 1 3 Output 2 4 Output 3 status signal encr...

Страница 24: ...nfig Example Set the DNS name of the device to room 442 NAME room 442 0x0D MODEL Functions Permission Transparency Set Get MODEL End User Public Description Syntax Set Get Get device model MODEL CR Re...

Страница 25: ...t USB connections immediately after running this command If the port was locked disconnect and reconnect the cable to reopen the port K Config Example RESET 0x0D SN Function Permission Transparency Se...

Страница 26: ...e Get was received Response is sent after every change in output HPD status ON to OFF Response is sent after every change in output HPD status OFF to ON and ALL parameters new EDID etc are stable and...

Страница 27: ...VM 2HDT 1 Loop Output 2 Output 1 3 Output 2 4 Output 3 dst_type EDID destination type usually input 0 input 1 output 2 default EDID dest_bitmap bitmap representing destination IDs Format XXXX X where...

Страница 28: ...y you If this product is returned uninsured you assume all risks of loss or damage during shipment Kramer Electronics will not be responsible for any costs related to the removal or re installation of...

Страница 29: ...RNING Disconnect the unit from the power supply before opening andservicing For the latest information on our products and a list of Kramer distributors visit our Web site where updates to this user m...

Отзывы: