The following Password Policy settings affect new user accounts for logging into the Gateway
Management Pages and joining a VIA meeting:
•
Alphanumeric
– Require at least one letter and one number to be included in a user
password.
•
At least one special character
– Require at least special character (like: !, @, #) to be
include in a user password.
•
At least one capital letter
– Require at least one capital letter to be include in a user
password.
•
Password minimum length
– Define a minimum number of characters for a user
password.
•
Apply password policy on basic mode
– Require all the above rules when creating the
Basic mode password (below).
•
VIA basic password
– Define the password needed to become moderator when in Basic
). To remove the password requirement, clear
the password field.
Certificate
VIA GO²
enables you to upload a custom SSL certificate to better provide for the security needs of
your organization.
To prevent damage to the system, make sure you upload files that can be used by the
system. If you are unsure of how to use this feature, contact technical support.
For information on how to create a certificate, see Creating an SSL Certificate for VIA,
available at:
www.kramerav.com/product/VIA GO²
After obtaining your certificate, install it on your VIA device.
The uploaded files must stay in the format of “server.crt” & “server.key”.
To upload an SSL certificate:
1. On the Certificate tab in the VIA settings template (see
), copy and paste the web server certificate.
The web server certificate is uploaded.
Do not upload the key file until the certificate file is finished uploading.
2. Copy and paste the key file.