NT-52P –
Kramer Protocol 3000
73
11.3.40 SECUR
Functions
Permission
Transparency
Set:
SECUR
Administrator
Public
Get:
SECUR?
Not Secure
Public
Description
Syntax
Set:
Start/stop security
#SECURSP
security_mode
CR
Get:
Get current security state
#SECUR?CR
Response
~nn@SECURSP
security_mode
CR LF
Parameters
security_mode
–
1
(On / enable security),
0
(Off / disable security)
Response Triggers
Notes
The permission system works only if security is enabled with the
SECUR
command
K-Config Example
Enable the permission system:
“#SECUR 0”,0x0D
11.3.41 SN
Functions
Permission
Transparency
Set:
-
-
-
Get:
SN?
End User
Public
Description
Syntax
Set:
-
-
Get:
Get device serial number
#SN?CR
Response
~nn@SNSP
serial_number
CR LF
Parameters
serial_number
– 11 decimal digits, factory assigned
Response Triggers
Notes
This device has a 14 digit serial number, only the last 11 digits are displayed
K-Config Example
“#SN?”,0x0D