Installing the F-010
5
5
5
Installing the F-010
To install the
F-010
you have to:
•
Install the Kramer inserts (see section
5.1
)
•
Connect the cables to the rear side (see section
5.2
)
•
Install the
F-010
inside the Ackermann floor box (see section
5.3
)
•
Connect the front panel ports (see section
5.4
)
5.1 Installing a Kramer Insert
To install a Kramer insert, do the following:
1. Unscrew the two screws holding the blank insert and remove it.
2. Place and align the required wall plate insert item over the opening.
3. Insert the two screws to fix the insert in place, and tighten them.
5.2 Connecting the Rear Side of the F-010
To connect the rear side cables, do the following:
1. Run the cables through the Ackermann under floor cable opening.
2. Connect the cables to the rear side of the inserts.
3. Connect the cables
1
to the rear side of the
F-010
(see section
5.2.1
), that
is, attach the:
RGBHV Terminal block output to the RGBHV acceptor (for
example, a display)
SDA and SCL terminal block connector to pins 12 and 15 on the XGA
output connector
4. Connect the 12V DC power supply to the power terminal blocks
(connect the wire labeled “+” to the +12V pin, and the wire labeled “–”
to the GND pin) taking care that the polarity is correct (see
Figure 2
).
1 We recommend that you use Kramer C-GM/XL cable, which has a molded male 15-pin HD connector installed at one end,
and the corresponding RGBHV coaxes exposed, pre-stripped and tinned at the other end, as well as two additional wires to
connect pins 12 and 15 for EDID support. For details, see our Web site at
http://www.kramerelectronics.com
)