The servo amplifier SCA-LE-30-03 is a powerful servo 
amplifier for brushed DC motors with an output range up to 
75 Watt. 
The standard operation mode is  

• 

Speed control with encoder feedback 

 
Additionally integrated operating modes are: 

Current control 

I x R control 

DC-Tacho control 

Voltage control 

These operating modes are described in the manual SCA-
LS-30-03. 
The required operation mode is to be selected with jumpers, 
which are accessible externally at any time. This SCA-LE-
30-03 servo amplifier is protected against over current and 
overheat. Due to the wide range of power supply voltage 
between 11 to 30 V DC the  
SCA-LE-30-03 can be used very flexible with different kinds of power supplies. Because of the linear output 
stage, no external choke is required. The robust aluminium case has been constructed for different 
methods of mounting it, therefore a fast and easy integration is provided. Screw terminals and a durable 
controller-design allow a fast and straightforward commissioning. 
 

Contents 

 

1.

 

Safety notes ...................................................................................................................................... 1

 

2.

 

Specification ..................................................................................................................................... 2

 

3.

 

Internal Components of this drive ................................................................................................... 3

 

4.

 

Description of inputs and outputs of power stage section, terminals (1)- (14) ............................ 4

 

5.

 

Description of inputs and outputs of encoder section, terminals (15)- (28) ................................. 6

 

6.

 

Configuration .................................................................................................................................... 8

 

7.

 

Operating modes ............................................................................................................................ 10

 

8.

 

Connection of inputs and outputs................................................................................................. 11

 

9.

 

Commissioning............................................................................................................................... 12

 

10.

 

Troubleshooting ............................................................................................................................. 13

 

11.

 

Dimensions ..................................................................................................................................... 13

 

12.

 

Versions of Text.............................................................................................................................. 13

 

 

1.  Safety notes 

1.1.  Skilled personnel 

The installation and commissioning have to be done only by skilled personnel. 

 

1.2.  Laws 

The user has to ensure the correct installation of the servo amplifier and additional equipment 
according to valid laws and rules. 

 

1.3.  Remove load 

For first commissioning the motor should run with free shaft which means without load. 

 

1.4.  Additional safety components 

Electronic components are not free of failure or damage. Therefore plants have to be installed with 
additional device and installation protecting components. A safe and stable state has to be ensured in 
the case of damage of some devices, wrong handling, cable disruption and other cases of any kind of 
malfunction. 
 

Summary of Contents for SCA-LE-30-03

Page 1: ...ds of mounting it therefore a fast and easy integration is provided Screw terminals and a durable controller design allow a fast and straightforward commissioning Contents 1 Safety notes 1 2 Specifica...

Page 2: ...quirements with standard EN 61800 3 1996 if the following directions are observed usage of a zinc plated mounting plate well connected to earth mounting of the drive by usage of toothed washers usage...

Page 3: ...ich is located on the upper side of the drive Both sections have their own PCB and are not connected internally 3 1 Power stage section Terminal numbers 1 to 14 The power stage section of this drive i...

Page 4: ...lue input is connected to an differential amplifier Input voltage range 10 V 10 V Input impedance 100 kOhm Definition of polarity positive set value Set value Set value negative set value Set value Se...

Page 5: ...on DO NOT connect Vcc and Power GND to the outputs Motor or Motor 4 2 Outputs 4 2 1 Auxiliary voltage output Enable V 13 The auxiliary voltage output Enable V provides a low resistant connection to pi...

Page 6: ...tion When the motor is connected in the right way it should turn clockwise at a positive output voltage Otherwise swap the motor lines to ensure that the motor is running clockwise at a positive volta...

Page 7: ...nge low signal 0 V 5 5 V Input voltage range high signal 13 0V 24 V 5 1 4 Vcc 26 5 1 5 Power GND 25 Power supply connector The encoder section of this drive has to be connected to DC Power supply volt...

Page 8: ...an encoder feedback are described in the manual SCA LE 30 03 6 2 Selection of Input for Set Value Jumper 5 6 J5 J6 Via Offset Pot Via Ext Pot Via Set Value 6 3 Selection of maximum input frequency of...

Page 9: ...triebstechnik mbH Zettachring 2 D 70567 Stuttgart Germany Tel 49 0 711 7221535 Fax 49 0 711 7221548 E mail mgmt e motion controls com 6 4 Location of Jumpers J9 1 2 3 4 5 6 7 8 9 10 11 12 13 14 151617...

Page 10: ...y 11 30 VDC Motor Tacho Tacho Set value Set value Reference Gnd Signal Enable In option see manual Gnd Power Gnd Tacho out Encoder B Encoder A Encoder A 28 27 26 25 24 23 22 21 20 19 18 17 16 15 Encod...

Page 11: ...iary voltage output enable V 13 and a potential free switch no Enable V 14 13 Enable In 8 2 Input for Set Value The set value for the speed can be set on three different ways 8 2 1 Input for set value...

Page 12: ...w 9 3 Presetting of potentiometers Original delivered servo amplifiers are adjusted to uncritical values and for easy adjustment by the user 9 4 Adjustment 1 Adjust max set value e g 10 V and turn pot...

Page 13: ...lue Current limitation adjusted too low Check potentiometer adjustment Imax Speed range too low Check potentiometer adjustment nmax Wrong operation mode Check jumper setting Bad connections Check conn...