background image

 

 

 

USER MANUAL 

 
 
 

 

 

 
 

● High voltage: 20x amplification up to +170V and -170V output voltage  

 

● DC to 500kHz -3dB large signal bandwidth and 100mA output current 

 

● Very low noise: ~840

µ

V

rms

 in DC - 10MHz; lower with capacitive loads  

 

●  No  overshoot  with  capacitive  loads:  bandwidth  changes  automatically  to             
ensure stability 

 

● Short-circuit protected output 

 

● Adjustable DC offset 

 
 

 

 

About this manual 

 
This user manual is an integral part of the 
Falco  Systems  WMA-100A  high  voltage 
amplifier  product.  Please  read  it  carefully 
and pay attention to the recommendations 
and instructions for safe use. 

 

 

The WMA-100A amplifier:  
getting started 

 

The Falco Systems WMA-100A model is a 
high  quality,  cost-effective,  high  voltage, 
linear  laboratory  amplifier.  Its  wide 
bandwidth and large voltage range make it 
an  excellent  choice  for  use  with  MEMS 

devices, EO-modulators, piezo positioning 
systems,  beam  steering,  ultrasonics, 
dielectric  studies,  and  many  other 
applications.  It  is  designed  to  be  fully 
stable  and  free  of  spurious  signals  with 
any capacitive load.  
The  amplification  is  20x  (fixed).  The 
amplifier has a range of -170V to +170V, a 
large 500kHz @ -3dB signal bandwidth, a 
typical  slew  rate  of  350V/μs,  and  a  noise 
level  of  ~840

µ

V

rms

  in  DC  –  10MHz.  The 

short-circuit  protection  with  a  fast  current 
limit  of  ±100mA  makes  this  amplifier 
suitable  for  both

 

normal  daily  laboratory 

use 

and 

automated 

measurement 

systems.  

Falco Systems WMA-100A    High Voltage Amplifier DC – 500kHz 

Summary of Contents for WMA-100A

Page 1: ...alco Systems WMA 100A model is a high quality cost effective high voltage linear laboratory amplifier Its wide bandwidth and large voltage range make it an excellent choice for use with MEMS devices E...

Page 2: ...e for indoor use in a class II environment domestic light industrial Non sinusoidal mains power generators cannot be used to power this product Detailed properties of the WMA 100A high voltage amplifi...

Page 3: ...t a 50W coaxial load resistor to the input Fig 2 The noise voltage at the output can be measured using a sensitive amplifier The output noise will be lower when the bandwidth of the amplifier is reduc...

Page 4: ...es should be used for connecting both the input and the output and their length should be minimized If not the cables will cause overshoot due to cable reflections an effect related to the finite spee...

Page 5: ...ferent capacitive loads Figure 6 Sine wave 300Vpp 1kHz Frequency Hz Amplification factor 20 15 10 5 0 10 2 10 3 10 4 10 5 10 6 10 7 0pF 100pF 1nF 10nF 100nF 1uF 10uF 20 15 10 5 0 10 2 10 3 10 4 10 5 1...

Page 6: ...wave 300Vpp 1kHz Figure 9 Square wave 300Vpp 100kHz Time ms Output voltage V 150 100 50 0 50 100 150 2 0 1 5 1 0 0 5 0 0 Time ms Output voltage V 150 100 50 0 50 100 150 2 0 1 5 1 0 0 5 0 0 Time s Ou...

Page 7: ...tep response are shown Figure 11a 300Vpp step response 10 90 up in 0 8 s Figure 11b 300Vpp step response 10 90 down in 0 8 s Time s Output voltage V 0 4 0 2 0 0 0 2 0 4 20 15 10 5 0 Time s Output volt...

Page 8: ...mits the speed at which the capacitor can be charged The bandwidth adjustments of the amplifier with different capacitive loads preventing overshoot are clearly visible Note the difference of the hori...

Page 9: ...gure 12c 1nF load Figure 12d 10nF load Time s Output voltage V 150 100 50 0 50 100 150 20 15 10 5 0 Time s Output voltage V 150 100 50 0 50 100 150 40 30 20 10 0 Time s Output voltage V 150 100 50 0 5...

Page 10: ...12f 1 F load Figure 12g 10 F load Time ms Output voltage V 150 100 50 0 50 100 150 2 0 1 5 1 0 0 5 0 0 Time ms Output voltage V 150 100 50 0 50 100 150 20 15 10 5 0 Time ms Output voltage V 150 100 5...

Page 11: ...ith a true rms voltmeter in DC 10MHz with the offset control switched to On In addition to the noise the short term drift of the offset is around 5mV Figure 15 Rms output noise voltage versus capaciti...

Page 12: ...apacitive and resistive loads no overshoot 5 Power 230V 50Hz AC 50W or 115V 60 Hz AC 50W Mains fuse 2x 0 25A 250V slow blow 230V version or 2x 0 5A 250V slow blow 115V version Safety Class I requires...

Page 13: ...he product resulting from use or operation in other ways than specified in the user manual Malfunctioning due to misuse or abuse of the product Malfunctioning occurring after changes or repairs have b...