3 Identification
3.1 Type code
3 Identification
3.1 Type code
DKC- 2400.BBBA.00002
1
2
3
4
5
6
7
Fig. 1: Type code
1
Type
2
Size
3
Shaft seal
4
Pressure stage pressure maintaining
valve
5
Suction-side two-way valve
6
Heating
7
Version index
Item Classification
Description
1
Type
DKC
o
Station with pumps of the K series
o
Pressure build-up up to 16 bars
DLC
o
Station with pumps of the L series
o
Pressure build-up up to 40 bars
2
Size
Corresponds to flow rate in [l/min] at 1450 min-1
3
Shaft seal
A
Standard mechanical seal
B
Mechanical seal of hard material
C
Standard radial shaft seal
D
Magnetic coupling
E
Mechanical seal with quench
F
High-temperature radial shaft seal
X
Special design
4
Pressure stage
pressure
maintaining valve
Small pump station
Large pump station
A
Without pressure maintaining valve
B
Internal pressure maintain-
ing valve
2 – 8 bar
3 – 7 bar
C
Internal pressure maintain-
ing valve
6 – 20 bar
7 – 16 bar
D
Internal pressure maintain-
ing valve
15 – 38 bar
16 – 34 bar
E
External pressure maintain-
ing valve
2 – 8 bar
3 – 7 bar
F
External pressure maintain-
ing valve
6 – 20 bar
7 – 16 bar
G
External pressure maintain-
ing valve
15 – 38 bar
16 – 34 bar
X
Special design
5
Suction-side
two-way valve
A
Without suction-side two-way valve
B
Suction-ide two-way valve, manually operated
C
Suction-side two-way valve, manually operated with limit switch
D
Suction-side two-way valve, electrically operated with limit switch
E
Suction-side two-way valve, pneumatically operated with limit switch
6
Heating
A
Without heating
B
Electrical heating system in station block
C
Fluid heating system in the station block
D
Electrical heating system in the station block and at the pumps
E
Fluid heating system in the station block and at the pumps
7
Version index
For internal administration
Tab. 2: Type code
8
OID 02en-GB Edition 2019-11