![KRAL CGF Скачать руководство пользователя страница 41](http://html.mh-extra.com/html/kral/cgf/cgf_operating-instructions-manual_2000364041.webp)
12 Servicing
12.7 Replacing the mechanical seal and ball bearing (outer bearing)
6
1
4
1
4
7
18
16
16
17
17
19
16
17
9.
Place the idle screws left and right of the main screw so that the fitting surfaces of the bearing
bushes contact the shaft of the main screw. Observe the alignment of the positioning pins
16
.
10.
Attention:
Ensure that the adapter sleeve
18
/straight pin
19
is not damaged when mounting the
cartridge housing. Take the hole
17
into account.
Slide the cartridge housing
1
over the pre-mounted idle screws and main screw.
11.
Size 15 – 660, 880
(figure left): Tighten the socket screws
6
with torque.
Size 2250– 3550
(figure right): Tighten the socket screws
7
with torque.
12. Mount and lightly grease the O-ring
4
in the flange cover.
12.7 Replacing the mechanical seal and ball bearing (outer bearing)
12.7.1
Removing the mechanical seal and ball bearing
Personnel qualification:
o
Fitter
Personal protective equipment:
o
Work clothing
o
Protective gloves
o
Safety boots
Aids:
o
Tool set, mechanical seal
Ä
o
Extractor
Requirement:
ü
Pump unit disconnected from the electrical power supply, deenergized and secured against being
switched back on
ü
Coupling removed
F
1
2
1.
Secure the position of the main screw
1
in the pump housing
2
. To do so, mount the main screw
stop for the outer bearing
F
to the pump housing.
7
6
5
4
1
2
3
2
3 1
7
23
22
7
3
2
24 25
2.
Remove the feather key
7
from the main screw
1
.
Operating instructions
OIC 18en-GB Edition 2020-01
41