8 Installation, removal
8.1 Dangers during installation
8 Installation, removal
8.1 Dangers during installation
The following safety instructions must be observed strictly:
o
Have all work carried out only by authorized qualified personnel.
o
Before installation ensure that the operating limits, NPSH values and ambient conditions are ob-
served.
o
Observe the tightening torques
Ä
o
Ensure that all the components can be accessed and that maintenance work can be carried out
easily.
8.2 Dangers during removal
The following safety instructions must be observed strictly:
o
Have all work carried out only by authorized qualified personnel.
o
Before beginning work, let the pump unit cool down to the ambient temperature.
o
Collect any discharging pumped liquid safely and dispose of it in an environmentally compatible
manner in accordance with the applicable local regulations.
o
Ensure that the collection tank for discharging pumped liquids is sufficiently large.
8.3 Installing the pump
The pumps can be operated in horizontal and vertical installation position.
Notice
Soiling in the pipe system impair the service life of the pump. If the pipe system is flushed using the
pump during the initial commissioning, an additional commissioning filter has to be installed temporarily
before the pump at the system (mesh width: 0.02 mm).
Personnel qualification:
o
Transport personnel
o
Fitter
Personal protective equipment:
o
Work clothing
o
Protective helmet
o
Protective gloves
o
Safety boots
Aids:
o
Mobile crane, forklift, hoisting equipment
WARNING
Risk of injury and damage to equipment through falling and toppling parts.
► Only fasten the pump on a stable load-bearing underground or stable load-bearing load support.
► Ensure that fastening elements and pipings are fastened sufficiently.
ATTENTION
Damage to motor through emitted pumped liquid.
► Do not install the pump above the motor.
ATTENTION
Damage to device through impurity in the pipe system.
► During welding work attach protective covers in front of the connecting flanges.
► Ensure when welding that welding beads and abrasive dust cannot get into the pipe system and
the pump.
► Ensure that a commissioning filter is installed when the pipe system is flushed and cleaned using
the pump.
18
OIC 18en-GB Edition 2020-01
Operating instructions