background image

14

14

GB

Wear suitable clothing

 

Do not wear wide clothing or jewellery, 

which can become entangled in mov-

ing parts.

 

Rubber gloves and non-slip shoes are 

recommended when working out-

doors.

 

Tie long hair back in a hair net.

Do not use the cable for purposes for 

which it is not intended

 

Do not use the cable to pull the plug 

out of the outlet. Protect the cable 

from heat, oil and sharp edges.

Take care of your tools

 

Keep your compressor clean in order 

to work well and safely.

 

Follow the maintenance instructions. 

 

Check the connection cable of the 

electric tool regularly and have it 

replaced by a recognised specialist 

when damaged.

 

Check extension cables regularly and 

replace them when damaged.

10 

Pull the plug out of the outlet

 

During non-use of the electric tool 

or prior to maintenance and when 

replacing tools such as saw blades, 

bits, milling heads.

11 

Avoid inadvertent starting

 

Make sure that the switch is switched 

off when plugging the plug into an 

outlet.

12 

Use extension cables for outdoors

 

Only use approved and appropriately 

identified extension cables for use 

outdoors.

 

Only use cable reels in the unrolled 

state.

13 

Remain attentive

 

Pay attention to what you are doing. 

Remain sensible when working. Do 

not use the electric tool when you are 

distracted.

14 

Check the electric tool for potential 

damage

 

Protective devices and other parts 

must be carefully inspected to ensure 

that they are fault-free and function 

as intended prior to continued use of 

the electric tool.

 

Check whether the moving parts 

function faultlessly and do not jam or 

whether parts are damaged. All parts 

must be correctly mounted and all 

conditions must be fulfilled to ensure 

fault-free operation of the electric 

tool.

 

Damaged protective devices and 

parts must be properly repaired or 

replaced by a recognised workshop, 

Intended use

The compressor is designed to generate com-
pressed air for compressed-air driven tools which 
can be driven with a theoretical air intake capacity 

180 l/min (e.g. tire infl ator, blow-out pistol and paint 
spray gun). Due to the limited air output it is not pos

-

sible to use the compressor to drive tools with very 

high air consumption (for example orbital sanders, 
rod grinders and hammer screwdrivers).

The equipment is to be used only for its prescribed 

purpose. Any other use is deemed to be a case of 
misuse. The user / operator and not the manufac-
turer will be liable for any damage or injuries of any 
kind caused as a result of this.

Please  note  that  our  equipment  has  not  been  de

-

signed for use in commercial, trade or industri-
al applications. Our warranty will be voided if the 

equipment is used in commercial, trade or industrial 
businesses or for equivalent purposes.

Safety information

Attention!

 The following basic safety 

actions must be taken when using this 

compressor in order to protect the user 

from electric shocks and the risk of injury 

and fi re. Read and follow these instruc

-

tions before using the equipment.

Safe work

Keep the work area orderly

 

Disorder in the work area can lead to 

accidents.

Take environmental influences into ac

-

count

 

Do not expose electric tools to rain.

 

Do not use electric tools in a damp 

or wet environment. There is a risk of 

electric shock! 

 

Make sure that the work area is well-

illuminated.

 

Do not use electric tools where there 

is a risk of fire or explosion.

Protect yourself from electric shock

 

Avoid physical contact with earthed 

parts (e.g. pipes, radiators, electric 

ranges, cooling units).

Keep children away

 

Do not allow other persons to touch 

the equipment or cable, keep them 

away from your work area.

Securely store unused electric tools

 

Unused electric tools should be stored 

in a dry, elevated or closed location 

out of the reach of children.

Do not overload your electric tool

 

They work better and more safely in 

the specified output range.

Содержание 3906132917

Страница 1: ...slation from the original instruction manual 12 17 FR Compresseur d air Traduction du manuel d origine 18 24 Nachdrucke auch auszugsweise bedürfen der Genehmigung Technische Änderungen vorbehalten Abbildungen beispielhaft Reproduction même partielle interdite sans autorisation Sous réserve de modifications techniques Illustrations non contractuelles ...

Страница 2: ...2 1 1 3 2 7 G H J K B C D E F A 4 6 8 C H J K 9 ...

Страница 3: ...3 5 3 4 4 4 6 8 5 4 2 5 7 ...

Страница 4: ...einer automatisierten Anlaufsteuerung ausgestattet Halten Sie Dritte vom Arbeitsbereich des Gerätes fern Tragen Sie einen Gehörschutz Die Einwirkung von Lärm kann Gehörverlust bewirken Warnung vor heißen Oberflächen Schutzklasse II Doppelisolierung Den Hahn nicht öffnen bevor der Luftschlauch angeschlossen ist Schutzbrille tragen DE Garantierter Schallleistungspegel des Gerätes 96 ...

Страница 5: ...Hersteller dieses Gerätes haftet nach dem gel tenden Produkthaftungsgesetz nicht für Schäden die an diesem Gerät oder durch dieses Gerät entste hen bei unsachgemäßer Behandlung Nichtbeachtung der Bedienungsanweisung Reparaturen durch Dritte nicht autorisierte Fach kräfte Einbau und Austausch von nicht originalen Ersatz teilen nicht bestimmungsgemäßer Verwendung Ausfällen der elektrischen Anlage be...

Страница 6: ... Elektrowerkzeug nicht wenn Sie unkonzentriert sind Bestimmungsgemäße Verwendung Der Kompressor dient zum Erzeugen von Druckluft für druckluftbetriebene Werkzeuge welche mit einer Theoretischen Lufteinlasskapazität 180 l min betrie ben werden können z B Reifenfüller Ausblaspis tole und Lackierpistole Aufgrund der begrenzten Luftfördermenge ist es nicht möglich Werkzeuge zu betreiben welche einen s...

Страница 7: ...1 Andere Teile können bei benutzung warm werden Stellen Sie den Kompressor nur auf einer ebenenFläche auf 14 Überprüfen Sie das Elektrowerkzeug auf eventuelle Beschädigungen Vor weiterem Gebrauch des Elekt rowerkzeugs müssen Schutzvorrich tungen oder leicht beschädigte Teile sorgfältig auf ihre einwandfreie und bestimmungsgemäße Funktion unter sucht werden Überprüfen Sie ob die beweglichen Teile e...

Страница 8: ...nbetriebnahme das Gerät unbedingt komplett montieren Netzanschluss Der Kompressor ist mit einer Netzleitung mit Schutzkontaktstecker ausgerüstet Dieser kann an jeder Schutzkontaktsteckdose 220 240V 50 Hz Sicherheitshinweise beim Farbspritzen Keine Lacke oder Lösungsmittel mit ei nem Flammpunkt von weniger als 55 C verarbeiten Explosionsgefahr Lacke und Lösungsmittel nicht erwärmen Explosionsgefahr...

Страница 9: ...tors Daten des Maschinen Typenschildes Daten des Motor Typenschildes welche mit 16 A abgesichert ist angeschlossen werden Achten Sie vor Inbetriebnahme darauf dass die Netzspannung mit der Betriebsspannung mit der Maschinenleistung auf dem Datenschild überein stimmt Lange Zuleitungen sowie Verlängerungen Kabel trommeln usw verursachen Spannungsabfall und können den Motoranlauf verhindern Bei niedr...

Страница 10: ... und Lagerung m Achtung Ziehen Sie vor allen Reinigungs und Wartungsar beiten den Netzstecker Verletzungsgefahr durch Stromstöße m Achtung Warten Sie bis das Gerät vollständig abgekühlt ist Verbrennungsgefahr m Achtung Vor allen Reinigungs und Wartungsarbeiten ist das Gerät drucklos zu machen Verletzungsgefahr Reinigung Halten Sie das Gerät so staub und schmutzfrei wie möglich Reiben Sie das Gerät...

Страница 11: ...5 C Außentemperatur betreiben Motor abkühlen lassen ggf Ursache der Überhitzung beseitigen Kompressor läuft jedoch kein Druck Rückschlagventil undicht Dichtungen kaputt Rückschlagventil muss von einer Fachkraft ausgetauscht werden Dichtungen überprüfen kaputte Dichtungen bei einer Fachwerkstatt ersetzen lassen Kompressor läuft Druck wird am Manometer angezeigt jedoch Werkzeuge laufen nicht Schlauc...

Страница 12: ...lectrical voltage Warning The unit is equipped with an automatic start control Keep others away from the work area of the device Wear ear muffs The impact of noise can cause damage to hearing Beware of hot parts Protection class II double shielded Do not open the cock before the air hose is attached Wear safety goggles Guaranteed sound power level of the device 96 ...

Страница 13: ...he product or damages caused by the product that occurs due to Improper handling Non compliance of the operating instructions Repairs by third parties not by authorized service technicians Installation and replacement of non original spare parts Application other than specified A breakdown of the electrical system that occurs due to the non compliance of the electric regu lations and VDE regulatio...

Страница 14: ...op Intended use The compressor is designed to generate com pressed air for compressed air driven tools which can be driven with a theoretical air intake capacity 180 l min e g tire infl ator blow out pistol and paint spray gun Due to the limited air output it is not pos sible to use the compressor to drive tools with very high air consumption for example orbital sanders rod grinders and hammer scr...

Страница 15: ...ork area There is a risk of explosion Paint vapors are easily com bustible Never set up or operate the equipment in the vicinity of a fire place open lights or sparking machines insofar as nothing different is speci fied in the operating manual Damaged switches must be replaced at a customer service workshop Do not use any faulty or damaged connection cables Do not use any electric tool on which t...

Страница 16: ...to avoid injuries due to the hose springing back Connect the fitting of your compressed air tool to the compressed air hose 5 of the compressor To disconnect this coupling again pull the quick coupling 4 back at the compressed air hose 5 Do not store or eat food and drink in the work area Paint vapors are harmful to your health The work area must exceed 30 m3 and sufficient ventilation must be ens...

Страница 17: ...ls to ensure proper operation Using the tyre inflation device fig 6 7 8 The compressed air tyre inflation device G is used to inflate car tyres With the corresponding accesso ries it can also be used to inflate and regulate bicycle tyres inflatable dinghies air mattresses balls etc Pressure can be released by actuating the vent valve 7 m Attention The manometer has not been officially calibrated A...

Страница 18: ...cannot be started up again by any unauthorized person m Important Store the compressor only in a dry location which is not accessible to unauthorized persons Always store upright never tilted Storage power cord hose and accessories Fig 2 The power cord can be stored sideways of the compressor The air hose can be stored in the tool cmpartment Transport The unit can be transported with the handle 1 ...

Страница 19: ... un système automatique de mise en route Veillez à maintenir les tierces personnes à distance de l appareil Portez une protection de l ouïe L exposition au bruit peut entraîner une perte de l ouïe Attention aux pièces brûlantes Catégorie de protection II double isolation Portez des lunettes de protection Ne pas ouvrir la vanne avant que le tuyau soit branché Niveau de puissance acoustique garanti ...

Страница 20: ...eur sur la responsabilité du fait des produits le fabricant n est pas tenu responsable pour tous les dommages à cet appareil ou pour tous les dommages resultant de l exploitation de cet ap pareil dans les cas suivants Mauvaise manipulation Non respect des instructions d utilisation Travaux de réparation effectués par des tiers par des spécialistes non autorisés Remplacement et installation de pièc...

Страница 21: ...onforme à l affectation Le compresseur sert à produire de l air comprimé pour les outils fonctionnant à l air comprimé qui peuvent être exploités avec un débit d aspiration d air théo rique 180 l min par ex pompes à pneus pistolets à air et pistolets de vernissage En raison du débit d air limité il n est pas possible d exploiter des outils dont la consommation en air est très élévée par ex pon ceu...

Страница 22: ...t que vous déta chez le raccord Vous éviterez de la sorte des blessures par le tuyau qui rebondit l outil électrique il convient de vérifier soigneusement que les dispositifs de protection et les autres pièces fonc tionnent parfaitement et conformé ment aux dispositions Vérifier que les pièces mobiles fonc tionnent parfaitement ne sont pas coincées et ne sont pas endomma gées Toutes les pièces doi...

Страница 23: ...angers et des pièces emportées par le souffle peuvent provoquer facile ment des blessures Ne dirigez pas le jet sur des personnes et ne nettoyez pas des vêtements au corps avec le pistolet à air Risque de blessure Ne touchez le compresseur qu au niveau de la poignée de transport 1 D autres pièces peuvent devenir chaudes pendant l utilisation Placez le compresseur uniquement sur une surface plane C...

Страница 24: ...ion si les lignes de raccor dement passent par des fenêtres ou interstices de portes Des pliures dues à une fixation ou à un chemine ment incorrects des lignes de raccordement Des points d intersection si les lignes de raccor dement se croisent Veillez à ce que l air aspiré soit sec et sans pous sière N installez pas le compresseur dans un endroit hu mide ni mouillé Le compresseur doit être utilis...

Страница 25: ...er régulièrement que les lignes de raccorde ment électriques ne sont pas endommagées Lors du contrôle veillez à ce que la conduite de rac cordement ne soit pas connectée au réseau Les lignes de raccordement électriques doivent cor respondre aux dispositions VDE et DIN en vigueur N utilisez que des lignes de raccordement dotées du signe H05VV F L indication de la désignation du type sur la ligne de...

Страница 26: ... ser vice communal d élimination des déchets un orga nisme agréé pour l élimination des déchets d équi pements électriques et électroniques ou le service d enlèvement des déchets Dépannage Panne Cause possible Solution Le compresseur ne marche pas Tension secteur pas présente Tension secteur trop basse Température extérieure trop faible Moteur surchauffé Contrôler le câble la fiche de contact le f...

Страница 27: ...27 ...

Страница 28: ...28 ...

Страница 29: ...29 ...

Страница 30: ...HS Directive X 2014 68 EU Druckgeräterichtlinie Pressure Equipment Directive X 2006 42 EC Maschinenrichtlinie Machinery Directive Annex IV Notified Body Notified Body No Reg No X 2000 14 EC Maschinenrichtlinie Machinery Directive Annex VI Noise measured LWA 95 8 dB A guaranteed LWA 96 dB A P 1 1 KW Notified Body TÜV SÜD industrie Service GmbH Westendstrasse 199 80686 München Deutschland Notified B...

Страница 31: ...31 ...

Страница 32: ...ion to the wrong mains voltage or current type misuse or inappropriate use such as overloading of the device or use of non approved tools or accesso ries failure to comply with the maintenance and safety regulations ingress of foreign bodies into the device e g sand stones or dust effects of force or external influences e g damage caused by the device being dropped and normal wear resulting from pr...

Отзывы: