SAFETY PILOT

This heater has a pilot with an Oxygen Depletion Sensing (ODS) safety shutoff system.  

The ODS/pilot shuts off the heater if there is not enough fresh air.

PIEZO IGNITION SYSTEM

 

This heater is equipped with an electronic piezo control system. This system requires  

one (1) AAA battery (provided).

2 GAS OPTIONS CAPABLE

Your heater is equipped to operate on either propane or natural gas. The heater is  

shipped from the factory ready for connecting to propane. The heater can easily be  

changed to natural gas by having your qualified installer follow the instructions on page 

18 and the markings on the heater.

State of Massachusetts

: The installation must be made by a licensed plumber or gas 

fitter in the Commonwealth of Massachusetts. Sellers of unvented propane or natural  

gas-fired supplemental room heaters shall provide to each purchaser a copy of  

527 CMR 30 upon sale of the unit. 

In the State of Massachusetts, unvented propane or natural gas-fired space heaters shall 

be prohibited in bedrooms and bathrooms. 

In the State of Massachusetts the gas cock must be a T-handle type. The State of 

Massachusetts requires that a flexible appliance connector cannot exceed three feet 

in length.

LOCAL CODES

 

Install and use heater with care. Follow all codes. In the absence of local codes, use the latest 

edition of The National Fuel Gas Code, ANSI Z223.1, also known as NFPA 54*. 

*Available from: 

 American National Standard Institute, Inc 

 

National Fire Protection Association, Inc.

 1430 Broadway 

 

 

 

 

 

1 Batterymarch Park

 New York, NY 10018 

 

 

 

 

Quincy, MA 02269-9101

This heater is designed for vent-free operation. State and local codes in some areas prohibit the 

use of vent-free heaters. 

PRODUCT FEATURES

This log set has been tested and approved to ANSI Z21.11.2 standard for Unvented Heaters 

and can be operated with the flue damper closed. State and local codes in some areas 

prohibit the use of vent-free heaters.

Содержание GLD2460R

Страница 1: ...iance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach you...

Страница 2: ...ance IMPORTANT Read instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIF...

Страница 3: ...s may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to operating this heater safely WARNING Any change to this...

Страница 4: ...lways operate heater with glass doors fully open 6 This log heater is designed to be smokeless If logs ever appear to be smoking turn off heater and call a qualified service technician Note During ini...

Страница 5: ...s complied with all the requirement of the authority having jurisdiction 12 Do not use heater if any part has been underwater Immediately call a qualified service technician to inspect the room heater...

Страница 6: ...a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms In the State of Massachusetts...

Страница 7: ...ore beginning assembly or operation of the product make sure all parts are present Compare parts with package contents list If any part is missing or damaged do not attempt to assemble install or oper...

Страница 8: ...Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additio...

Страница 9: ...as heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct vent gas applia...

Страница 10: ...or Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heat...

Страница 11: ...tilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 8 through 10 WARNING Before installing in a solid flue burning firebox the chimney flue and fi...

Страница 12: ...MUM NONCOMBUSTIBLE MATERIAL CLEARANCE If Not Using Mantel You must have noncombustible material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1...

Страница 13: ...between mantel shelf and top of fireplace opening a hood is not necessary see Fig 5 Noncombustible Material Distance Requirements for Safe Installation 8 in or more Noncombustible material okay Less...

Страница 14: ...the flue damper open only Raise the mantel to an acceptable height FLOOR CLEARANCES a If installing appliance on floor level you must maintain the minimum distance of 14 in to combustibles see Fig 7...

Страница 15: ...vented operation If reasons number 1 or 2 above apply to you you must permanently open chimney flue damper You must install the damper clamp accessory not provided This will ensure vented operation se...

Страница 16: ...Connect approved flexible gas hose to gas regulator of heater see Fig 11 Note Never apply pipe sealant to flare fitting threads 2 Locate masonry screws in hardware package 3 Position heater base assem...

Страница 17: ...e Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use only a new black iron...

Страница 18: ...e the width of a quarter and turn knob clockwise until the knob locks into the NG position see Fig 15 3 Remove steel or metal hex plug with wrench provided from natural gas inlet of regulator and inst...

Страница 19: ...eaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve...

Страница 20: ...ig 19 Installing Log 3 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or pers...

Страница 21: ...wired to the valve place receiver to the side of the log set See Fig 27 Fig 25 Fig 26 Fig 27 Black Wire Red Wire Batteries are included Remove batteries when depleted Install replace the batteries acc...

Страница 22: ...is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately cal...

Страница 23: ...low the thermocouple to warm up and to allow air to bleed from the gas system Release the control knob Note If the pilot goes out repeat steps 7 8 9 and 10 6 Push in the control knob slightly and turn...

Страница 24: ...t to off position Manually operated solenoid OFF MODE Changes unit from manual mode to thermo mode SET Sets temperature in thermo mode LCD Liquid Crystal Display 1 DISPLAY Indicates CURRENT room tempe...

Страница 25: ...he SET key until the desired set temperature is reached By pressing and holding the set key the LCD screen set numbers will increase from 45 to 99 then restart over at 45 2 Next release the SET key Th...

Страница 26: ...remote control that was included with your gas logs It is not intended to replace the information in the Owners Manual Please refer to the Owners Manual for detailed information about your appliance...

Страница 27: ...ame Pattern with Control Knob Set to High Flame 5 Fig 47 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 BURNER FLAME PATTERN Fig 46 shows a correct burner flame pattern Fig 47 sho...

Страница 28: ...Clean the pilot assembly also WARNING Failure to keep primary air openings of burners clean may result in sooting and property damage CAUTION You must keep control areas burner and circulating air pas...

Страница 29: ...ow air through the air inlet hole You may blow through a drinking straw if compressed air is not available CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean the cabinet to remov...

Страница 30: ...nitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrode 2 Replac...

Страница 31: ...ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Burner orifice see Care and Maintenance page 28 or contact customer service 2 Cont...

Страница 32: ...duces unwanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement page 30 2 Gas leak See Warning Statement at the top of page 30 3 Low fuel supply 1 Ventilate roo...

Страница 33: ...ZY WORLD PHONE NUMBER 800 776 9425 When contacting your dealer have ready Your name Your address Model and serial numbers of your heater How heater was malfunctioning Type of gas used natural or propa...

Страница 34: ...t WYL009 01 1 5 Regulator Bracket WYL007 01D 1 6 Control Case UN3 1 7 Remote Control CON1001TH 1 8 DF Regulator RV83F1 4 9 1 8 1 Regulator Plug PF120820 2 9 Air Shutter Assembly FBB28D11 1 10 Fuel Sel...

Страница 35: ...35 GLD2460...