24
REMOTE CONTROL OPERATION
Fig. 29
Fig. 30
Fig. 31
MATCHING SECURITY CODES
When matching security codes, be sure slide button on the receiver is in the REMOTE position.
To program the remote receiver to LEARN a new security code, press and release the LEARN
button on the top of the remote receiver, and then press ON or OFF button on the transmitter.
A change in the beeping pattern at the receiver, indicates the transmitter's code has been
programmed into the receiver.
REMOTE CONTROL OPERATION
This appliance must not be used with glass
doors in the closed position.
This can lead to pilot outages and severe
sooting outside the fireplace.
The transmitter operates on two AAA batteries.
KEY SETINGS
ON
- Operates unit to on position, Manually operated
solenoid ON.
OFF
- Operates unit to off position, Manually operated
solenoid OFF.
MODE
-Changes unit from manual mode to thermo
mode.
SET
- Sets temperature in thermo mode.
LCD Liquid Crystal Display
1. DISPLAY Indicates CURRENT room temperature.
2. °F or °C Indicates degrees Fahrenheit or Celsius.
3. FLAME Indicates bumer/valve in operation.
4. ROOM Indicates remote is in THERMO operation.
5. TEMP Appears during manual operation.
6. SET Appears during time the of setting the desired
temperature in the thermo operation.
SETTING°F/°C SCALE
The factory setting for temperature is °F. To change
this setting to°C .
First
Press the ON key and the OFF key on the transmitter
at the same time this will change from°F to °C. Follow
this same procedure to change from°C back to°F.
MANUAL FUNCTION
To operate the system in the manual “MODE” do
the following.
ON OPERATION
Press the ON key and the appliance flame will
come on.
During this time the LCD screen will show
ON (Fig. 33).
ON BUTTON
OFF BUTTON
MODE BUTTON
SET BUTTON
Fig. 32
Fig. 33