4
1. Do not place propane/LP supply tank(s) inside any structure. Propane/LP supply tank(s)
must be placed outdoors.
2. This heater should not be installed in a bedroom or bathroom unless installed as a
vented appliance.
3. Solid fuels should not be burned in a fireplace in which vent-free log set is installed.
4. Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using
these added items can cause sooting. Do not add lava rock around base. Rock and de
bris could fall into the control area of heater. After servicing, always replace screen
before operating heater.
5. If fireplace has glass doors, never operate this heater with glass doors closed. If you
operate heater with doors closed, heat will build up inside fireplace and cause glass to
burst. If fireplace opening has vents at the bottom, you must open the vents before
operating log set. Always operate heater with glass doors fully open.
6. This log heater is designed to be smokeless. If logs ever appear to be smoking, turn off
heater and call a qualified service technician.
Note:
During initial operating, slight smoking could occur due to log curing and heater
burning off manufacturing residues.
7. To prevent the creation of sooting, follow the instructions (see
Care and Maintenance,
page 28).
8. Before using furniture polish, wax, carpet cleaner, or similar products, turn heater off. If
heated, the vapor from these products may create a white powder residue within burner
box or on adjacent walls and furniture.
9. This heater needs fresh, outside air ventilation to run properly. This heater has an
Oxygen Depletion Sensor (ODS) safety shutoff system. The ODS shuts down the
heater if not enough fresh air is available. (See Air For Combustion And Ventilation,
pages 8-10)
10. To prevent performance problems, do not use propane/LP fuel tank of less than
100 lbs. capacity.
11. Do not run heater where flammable liquids or vapors are used or stored under
dusty conditions.
Содержание GLD2460R