Kozy-World GLD2460R Скачать руководство пользователя страница 1

This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is 

installed. Provisions for adequate combustion and ventilation air must be provided. 

Refer to 

Air For Combustion and Ventilation 

section on page 8 of this manual.

INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual 

for future reference.

WARNING

: This appliance is 

equipped for (Natural and  

Propane) gas. Field 

conversion is not permitted 

other than between natural 

or propane gases.

 CAUTION - FOR YOUR SAFETY

 WARNING

: IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED

EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY  

DAMAGE, PERSONAL INJURY, OR LOSS OF LIFE.

– Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any 

other appliance.

WHAT TO DO IF YOU SMELL GAS

•  Do not try to light any appliance.

•  Do not touch any electrical switch; do not use any phone in your building.

•  Immediately call your gas supplier from a neighbor’s phone. Follow the gas

 

supplier’s instructions.

•  If you cannot reach your gas supplier, call the fire department.

– Installation and service must be performed by a qualified installer, service agency

  or the gas supplier.

This appliance may be installed in an aftermarket, permanently located manufactured 

(mobile) home, where not prohibited by local codes. This appliance is only for use 

with propane or natural gas. This appliance is equipped with a simple means to 

switch between propane and natural gas. Field conversion by any other means 

including the use of a kit is not permitted.

VENT FREE GAS LOG

MODEL #GLD2460R

  

Kozy-World

 

®

 

 

Made in China   Printed in China    WM-GLD2460-1103

Questions about installation, operation, or troubleshooting?

 Before returning to your retailer, call  

the 

KOZY WORLD PHONE NUMBER (800) 776-9425

.

HEATER IS PRESET FOR 

PROPANE AT FACTORY SEE 

INSTALLATION INSTRUCTIONS 

FOR NATURAL GAS HOOK UP

Содержание GLD2460R

Страница 1: ...iance Do not touch any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach you...

Страница 2: ...ance IMPORTANT Read instructions and warnings carefully before starting installation Failure to follow these instructions may result in a possible fire hazard and will void the warranty PRODUCT SPECIF...

Страница 3: ...s may be present even though no odor exists Make certain you read and understand all warnings Keep this manual for reference It is your guide to operating this heater safely WARNING Any change to this...

Страница 4: ...lways operate heater with glass doors fully open 6 This log heater is designed to be smokeless If logs ever appear to be smoking turn off heater and call a qualified service technician Note During ini...

Страница 5: ...s complied with all the requirement of the authority having jurisdiction 12 Do not use heater if any part has been underwater Immediately call a qualified service technician to inspect the room heater...

Страница 6: ...a copy of 527 CMR 30 upon sale of the unit In the State of Massachusetts unvented propane or natural gas fired space heaters shall be prohibited in bedrooms and bathrooms In the State of Massachusetts...

Страница 7: ...ore beginning assembly or operation of the product make sure all parts are present Compare parts with package contents list If any part is missing or damaged do not attempt to assemble install or oper...

Страница 8: ...Tight Construction The air that leaks around doors and windows may provide enough fresh air for combustion and ventilation However in buildings of unusually tight construction you must provide additio...

Страница 9: ...as heater logs __________BTU hr Gas water heater 30 000 BTU hr Other gas appliances ____BTU hr Vent free heater 26 000 BTU hr Total ____BTU hr Total 56 000 BTU hr Do not include direct vent gas applia...

Страница 10: ...or Combustion and Ventilation for required size of ventilation grills or ducts IMPORTANT Do not provide openings for inlet or outlet air into attic if attic has a thermostat controlled power vent Heat...

Страница 11: ...tilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation pages 8 through 10 WARNING Before installing in a solid flue burning firebox the chimney flue and fi...

Страница 12: ...MUM NONCOMBUSTIBLE MATERIAL CLEARANCE If Not Using Mantel You must have noncombustible material s above the fireplace opening Noncombustible materials such as slate marble tile etc must be at least 1...

Страница 13: ...between mantel shelf and top of fireplace opening a hood is not necessary see Fig 5 Noncombustible Material Distance Requirements for Safe Installation 8 in or more Noncombustible material okay Less...

Страница 14: ...the flue damper open only Raise the mantel to an acceptable height FLOOR CLEARANCES a If installing appliance on floor level you must maintain the minimum distance of 14 in to combustibles see Fig 7...

Страница 15: ...vented operation If reasons number 1 or 2 above apply to you you must permanently open chimney flue damper You must install the damper clamp accessory not provided This will ensure vented operation se...

Страница 16: ...Connect approved flexible gas hose to gas regulator of heater see Fig 11 Note Never apply pipe sealant to flare fitting threads 2 Locate masonry screws in hardware package 3 Position heater base assem...

Страница 17: ...e Apply pipe joint sealant lightly to male threads This will prevent excess sealant from going into pipe Excess sealant in pipe could result in clogged heater valves CAUTION Use only a new black iron...

Страница 18: ...e the width of a quarter and turn knob clockwise until the knob locks into the NG position see Fig 15 3 Remove steel or metal hex plug with wrench provided from natural gas inlet of regulator and inst...

Страница 19: ...eaks immediately 6 Reconnect heater and equipment shutoff valve to gas supply Check reconnected fittings for leaks Test Pressures Equal To or Less Than 1 2 PSIG 3 5 kPa 1 Close equipment shutoff valve...

Страница 20: ...ig 19 Installing Log 3 WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or pers...

Страница 21: ...wired to the valve place receiver to the side of the log set See Fig 27 Fig 25 Fig 26 Fig 27 Black Wire Red Wire Batteries are included Remove batteries when depleted Install replace the batteries acc...

Страница 22: ...is heavier than air and will settle on the floor WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Immediately cal...

Страница 23: ...low the thermocouple to warm up and to allow air to bleed from the gas system Release the control knob Note If the pilot goes out repeat steps 7 8 9 and 10 6 Push in the control knob slightly and turn...

Страница 24: ...t to off position Manually operated solenoid OFF MODE Changes unit from manual mode to thermo mode SET Sets temperature in thermo mode LCD Liquid Crystal Display 1 DISPLAY Indicates CURRENT room tempe...

Страница 25: ...he SET key until the desired set temperature is reached By pressing and holding the set key the LCD screen set numbers will increase from 45 to 99 then restart over at 45 2 Next release the SET key Th...

Страница 26: ...remote control that was included with your gas logs It is not intended to replace the information in the Owners Manual Please refer to the Owners Manual for detailed information about your appliance...

Страница 27: ...ame Pattern with Control Knob Set to High Flame 5 Fig 47 Incorrect Pilot Flame Pattern with Control Knob Set to High Flame 5 BURNER FLAME PATTERN Fig 46 shows a correct burner flame pattern Fig 47 sho...

Страница 28: ...Clean the pilot assembly also WARNING Failure to keep primary air openings of burners clean may result in sooting and property damage CAUTION You must keep control areas burner and circulating air pas...

Страница 29: ...ow air through the air inlet hole You may blow through a drinking straw if compressed air is not available CABINET Air Passageways Use a vacuum cleaner or pressurized air to clean the cabinet to remov...

Страница 30: ...nitor electrode is broken 3 Ignitor electrode is not connected to ignitor cable 4 Ignitor cable is pinched or wet 5 Damaged ignitor cable 6 Bad piezo ignitor 7 Low battery 1 Replace electrode 2 Replac...

Страница 31: ...ODS pilot is lit 1 Burner orifice is clogged 2 Burner orifice diameter is too small 3 Inlet gas pressure is too low 1 Burner orifice see Care and Maintenance page 28 or contact customer service 2 Cont...

Страница 32: ...duces unwanted odors 1 Heater is burning vapors from paint hair spray glues etc See IMPORTANT statement page 30 2 Gas leak See Warning Statement at the top of page 30 3 Low fuel supply 1 Ventilate roo...

Страница 33: ...ZY WORLD PHONE NUMBER 800 776 9425 When contacting your dealer have ready Your name Your address Model and serial numbers of your heater How heater was malfunctioning Type of gas used natural or propa...

Страница 34: ...t WYL009 01 1 5 Regulator Bracket WYL007 01D 1 6 Control Case UN3 1 7 Remote Control CON1001TH 1 8 DF Regulator RV83F1 4 9 1 8 1 Regulator Plug PF120820 2 9 Air Shutter Assembly FBB28D11 1 10 Fuel Sel...

Страница 35: ...35 GLD2460...

Отзывы: