Follow vent pipe manufacturer‟s installation instructions for horizontal terminations. Include the required 1
-
1/2” (38 mm) top c
learance (at
wall pass-
thru) and 1” (25 mm) sides and bottom clearances for approved rigid vent systems.
CAUTION: Due to high temperatures, this fireplace should be located out of traffic areas and away from furniture and draperies.
HORIZONTAL TERMINATIONS
Follow vent pipe manufacturer‟s installation instructions for vertical terminations. A minimum 1” (25 mm) clearance on all s
ides of vertical
vent pipe must be maintained.
VERTICAL TERMINATIONS
FRAMING
IMPORTANT: Vent cap location must be in compli-
ance with the guidelines on page #21
of this manual
.
IMPORTANT: To achieve the minimum venting requirements, a minimum of 26” (660 mm) from the floor or hearth the fireplace is setting on to
the top of vent pipe is required.
IMPORTANT: WALL PASS-THRU REQUIRED FOR ALL HORIZONTAL RUNS. REFER TO VENT MANUFACTURER‟S TO DETERMINE
WHICH PASS-THRU WILL WORK BEST FOR YOUR APPLICATION AND WALL THICKNESS.
PAGE 11
CAUTION: Cold air transfer area. The surrounding fireplace chase must comply with all clearances as outlined in this manual and be con-
structed in compliance with local building codes. Outside walls should be insulated to prevent cold air from entering room.
1-1/2” (38 mm) clearance
at top for wall pass-thru
26” (660 mm) min.
to top of vent pipe
TYPICAL HORIZONTAL TERMINATION
1-1/2” (38 mm) from inside framing
to stud wall
39” (991 mm) to
top of framing
KOZY HEAT CORNER CABINET FRAMING
Refer to vent pipe manufacturer‟s
instructions for specific height (H)
and width (W) framing dimensions.