Determine the exact position of your fireplace, including hearth height, width, and depth, (if applicable). If possible, place fireplace in such a
manner that the vent termination will be placed between two studs, eliminating the need for additional framing.
WARNING
:
Install fireplace on hard metal or wood surface
extending the full width and depth of fireplace. Minimum plat-
form size: 36” (984 mm) wide x
11” (610mm) deep.
FIRE HAZARD: Do NOT install directly on carpeting, vinyl, or
any combustible material other than wood.
If masonry is to be used (optional), prepare the necessary foundation for the masonry load. When masonry construction is being used, a lintel
(#617) must be used over the top of fireplace to support the added weight.
FRAMING
WALL ENCLOSURE ROUGH OPENING
IMPORTANT: Framing dimensions should allow for wall cover-
ing thickness and fireplace facing materials. If using a hearth,
adjust rough opening size as necessary to maintain at least the
minimum clearance requirements.
IMPORTANT: NON-COMBUSTIBLE FACING MATERIAL MAY BE
APPLIED OVER (BUT NOT DIRECTLY TO) FIREPLACE FACE.
THIS WILL PREVENT THE FACING MATERIAL FROM FALLING
OFF DUE TO EXPANSION OF THE FACE WHEN HEATED. DO NOT
OBSTRUCT THE FLOW OF VENTILATION AIR.
Build hearth to desired size and height. If a hearth extension is desired, combustible material may be used.
NOTE: Provide adequate clearance in front of fireplace to oper-
ate lower grill, open and close optional decorative doors / full door
faces, access the control valve, installation of gas line, fan, etc.
NOTE: Consider height of hearth
finish material (stone, brick, etc.) when building
fireplace platform. The bottom of the fireplace
must be level with finished hearth to allow for
lower grill operation and proper fit of optional
decorative full door faces.
WARNING: DO NOT OBSTRUCT UPPER AND LOWER
GRILL OPENINGS. ROOM AIR ENTERS THROUGH THE
LOWER PASSAGE, IS HEATED AND EXITS THROUGH THE
UPPER PASSAGE. BLOCKING THESE PASSAGES MAY
RESULT IN OVERHEATING, CREATING A POTENTIALLY
HAZARDOUS SITUATION.
PAGE 10
32-1/4”
(819 mm)
36-1/2”
(927 mm)
11-1/4”
(286 mm)
MANTEL REQUIREMENTS
(APPLIES TO BOTH HORIZONTAL AND VERTICAL VENTING TERMINATIONS)
32-1/4” (819 mm) High x 36-1/2”(927 mm) Wide x 11-1/4” (286 mm) Deep.