OPTIONAL:
Disconnect ON/OFF
rocker switch wires from
the gas valve.
If
desired, a thermostat (wireless style also available), wall switch,
or remote control assembly may be used to turn the fireplace „OFF‟
and „ON‟. Only ONE of these may be installed. Follow instructions
included with each assembly.
WALL SWITCH / THERMOSTAT:
Run low-voltage (thermostat) wires from terminals on the gas valve to
the desired location of wall switch or thermostat.
Attach the appropriate connectors to wall switch / thermostat wires
and connect to the top and bottom terminals marked TH / TPTH on
the gas valve.
REMOTE CONTROL:
Follow instructions included with the remote control
.
IMPORTANT
:
The insulated cover included with the remote
control must be placed over the remote receiver to prevent
overheating.
Remote Control Wiring Diagram
Thermostat Wiring Diagram
THERMOSTAT / WALL SWITCH / REMOTE
PAGE 21
CAUTION: DO NOT CONNECT HIGH VOLTAGE
(115V) WIRE TO THE GAS VALVE!
IMPORTANT: If ON/OFF rocker switch wires are not
disconnected, the ON/OFF rocker switch on the millivolt
board must be in the „OFF‟ position for proper operation
of any of these components.
If rocker switch is „ON‟, the fireplace burner will operate until it is
turned „OFF‟ by the rocker switch. A wall switch, thermostat, or
remote control will not turn the fireplace „OFF‟ when it has been
turned „ON‟ by the rocker switch.
NOTE: The fireplace must be turned „ON‟ and „OFF‟
by the same method. For example: If fireplace is turned
„ON‟ by the remote control, it must be turned „OFF‟ by
the remote control.
NOTE: INSTALLATION OF THERMOSTAT OR WALL SWITCH
SHOULD ONLY BE DONE BY A QUALIFIED INSTALLER
.
Figure L-1
Figure L-2