CONNECT THE ROCKER SWITCH WIRES TO THE VALVE
1.
Slide the remaining connectors on the rocker switch wire to the top and bottom terminals marked „TH‟ on the valve.
Completed Shroud Installation
1.COMPLETE THE FAN INSTALLATION:
This unit comes complete with a fan, speed control and temperature limit switch assembly already installed. A three-prong (grounding) plug is
attached to the end of the 8 ft. fan electrical cord for protection against shock hazard. Do not remove the grounding prong from the plug. Do not
allow any excess fan cord to touch the firebox.
NOTE: Speed control box is installed on the right side of the fireplace behind the lower grill. A mounting stud has been provided on the left side
of the fireplace (behind the lower grill) to re-position this speed control box to the left side if desired.
1.
Attach the limit switch on the left side of the millivolt board under the firebox.
2.
Plug fan cord into the nearest, properly grounded receptacle.
Note: The fan will not operate unless the speed control has been turned on. The fan will not turn on until sufficient heat is applied to the thermo-
static control switch. The fan will then turn on and off automatically when the fireplace heat and cools. Adjust fan to desired speed while it is
running.
NOTE: THIS FAN SYSTEM, WHEN INSTALLED, MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE WITH LOCAL BUILDING CODES, OR IN
THE ABSENCE OF LOCAL BUILDING CODES, WITH THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70.
110V-120V
CAUTION:
WHEN INSTALLATION OF THE MILLIVOLT BOARD IS COMPLETE, CHECK TO ENSURE THAT
THERE ARE NO WIRES, FLEXLINES, ETC. TOUCHING THE FAN TERMINALS.
PAGE 18
Figure I-1