![kozy heat Chaska-34 LOG Скачать руководство пользователя страница 9](http://html.mh-extra.com/html/kozy-heat/chaska-34-log/chaska-34-log_installation-and-operation-manual_1999734009.webp)
4.0 CLEARANCES
4.1 Fireplace Insert Placement
Considerations
• This fireplace must be installed on a level surface capable of
supporting the fireplace insert and venting.
• Due to high surface temperatures, the fireplace insert
should be located out of traffic and away from furniture and
draperies.
• This fireplace insert may be installed in a bedroom.
• Please be aware of the large amount of heat this fireplace
insert will produce when determining a location.
4.2 Vent Termination Clearances
• Approved vent caps require 12 in. (305 mm) clearance to
intersecting walls, overhangs, or eaves, as verified by test.
Figure 4.3, Non-Combustible Flooring
Figure 4.2, Side Wall Clearances
4.3 Combustible Material Clearances
4.3.1 Sidewall Clearances
12”
(305mm)
Figure 4.1, Vent Cap Clearance
4.3.2 Projection Requirements
7 in. (178 mm) of non-combustible flooring in front of the
appliance is required if this appliance is directly installed on the
fireplace floor. See Figure 4.3.
Combustible flooring is allowed 1 in. (25 mm) below the
appliance. This airspace must be maintained. See Figure 4.4.
Figure 4.4, Combustible Flooring
11
Содержание Chaska-34 LOG
Страница 32: ......