5.6 Vent System Connection (applies
to both venting options)
5.6.1 Secure Vent System to Air Duct
1. Place previously removed air duct (5.2 Fireplace Insert Air
Duct Removal, on page 12) into existing fireplace opening.
See Figure 5.5, Secured Vent System.
2. Apply a bead of sealant (provided) around exhaust pipe (red
marking), then slide the exhaust pipe inside collar marked
‘Exhaust’ on air duct.
3. Secure the exhaust pipe to the collar on the air duct with (3)
1/2 in. (13 mm) self-tapping screws, provided. Apply additional
sealant around joint to ensure an air tight seal. See Figure
5.5.
4. Apply a liberal bead of sealant (provided) around the collar
on the air duct. Slide combustion intake pipe over collar.
5. Secure the combustion intake pipe to the collar on the air
duct with (3) 1/2 in. (13 mm) self-tapping screws, provided.
Apply additional sealant around joint to ensure an air tight
seal.
6. Slide the insert into fireplace. See Figure 5.5.
Figure 5.5, Secured Vent System
5.6.2 Secure Air Duct to Fireplace Insert
1. Insert air duct pull handle (included) through the access slot
the at top of insert, placing hook through hole in pull rod.
2. Simultaneously pull the air duct forward and push the insert
backward into the fireplace opening until the air duct is
seated and the insert is properly positioned.
3. Use the slots at top of fireplace to secure the air duct to the
fireplace insert with (2) 1/2 in. (13 mm) sheet metal screws
(included in components packet). See Figure 5.6, Seated Air
Duct.
4. Use the pull rod handle to slide pull rod back to its starting
position. Remove pull rod handle.
5. If necessary, level the insert by threading leveling bolts
(included in components packet) into nuts at the bottom of
the insert - 2 each side.
Secure with (2) screws
Pull rod
Figure 5.6, Seated Air Duct (shown without venting attached for clarity purposes only)