26
GAS FIREPLACE INSERT SETUP
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#CSK-29-MV R.6 January 2019
9.3 Control Board Removal and Installation
WARNING: If burner and/or pilot have been burning, use appropriate
protection to avoid burns or damage to personal property before
removing any components. DO NOT OPERATE THIS APPLIANCE
WITHOUT THE SEALING GASKET (LOCATED UNDER THE CONTROL
BOARD) IN PLACE. IF GASKETING IS DAMAGED, IT MUST BE REPLACED.
CAUTION: Check all connections for leaks with soapy water, whether
field or factory made.
9.3.1 Control Board Removal
1. Remove the safety barrier.
2. Turn the fireplace off.
3. Locate the manual valve installed by your qualified service
technician. Turn the manual valve clockwise to the OFF position.
4. Disconnect any wall switch, remote control, or thermostat from
the top and bottom terminals on the gas valve, OR unplug all
components from receptacle and disconnect all wiring harnesses
attached to the gas valve.
5. Remove the glass frame assembly and log set.
6. Remove the burner assembly, secured with (2) screws.
7. Remove refractory panels (if installed).
8. Remove burner, secured with (2) screws at the back of the
firebox.
9. Remove the primary and secondary burner heat shields.
10. Remove (10) screws securing control board. Remove the control
board.
9.3.2 Control Board Installation
1. with mounting studs at the bottom of the firebox.
VERIFY SEALING GASKET IS IN PLACE ON THE BOTTOM OF THE
FIREBOX. Secure with screws previously removed.
2. Secure the control board with screws previously removed.
3. Reinstall the burner heat shields by placing the primary burner
heat shield on top of the control board. Position the cut-outs
over pilot assembly and burner orifice, centering from side-to-
side and as far back as possible.
4. Reinstall burner (2) screws.
5. Reinstall refractory panels (if used).
6. Reinstall burner assembly. Verify the burner tube is positioned
over burner orifice. Secure with (2) screws previously removed.
7. Reinstall log set.
8. Reconnect any wall switch, remote control, or thermostat wires
to the top and bottom terminals on the gas valve, OR reconnect
all wiring harnesses to the gas valve. Plug all components into an
electrical outlet.
9. Reinstall the glass frame assembly and safety barrier.
10. Turn the manual valve counter clockwise to the ON position.
11. Verify proper log placement, operation of fireplace, and any
electrical components.
ON
OFF
Figure 9.3, Control Board Removal and Installation
BURNER
ASSEMBLY
BURNER
CONTROL BOARD
SECONDARY BURNER
HEAT SHIELD
PRIMARY BURNER
HEAT SHIELD