8.2 #CK29-LMK Low Mantel Kit
This low mantel kit is for use only with safety barriers CK29-PSF and
CK29-RSF.
REMOVE (2) SCREWS AS SHOWN LOCATED AT THE BACK
OF THE SCREEN FRONT AND ALIGN THE HEAT DEFLECTOR
POSITION THE HEAT DEFLECTOR BY SLIDING IT
UNDER THE MOUNTING TABS AS SHOWN
REPLACE (2) SCREWS THROUGH THE HOLES IN
THE MOUNTING TAB AND HEAT DEFLECTOR
GASKET MUST BE IN CONTACT
WITH SHROUD
CK29-RSF (SHOWN)
HEAT DEFLECTOR