FACING AND FINISHING
23
8.3 Shroud Installation
CAUTION: Trim panels or surrounds must not seal ventilation
openings in existing fireplace that this appliance is installed in.
Draft relief openings must not be covered or blocked.
WARNING: The flow of combustion and ventilation air must not be
obstructed.
1. Remove the upper louver by lifting up and out of the mounting
flanges.
2. Remove lower louver by lifting the louver out of the slots on the
mounting bracket.
3. Remove the glass assembly.
4. Align the mounting holes on the shroud to the corresponding
mounting nuts on the sides of the insert metal cabinet.
5. Secure with (4) truss head screws (provided).
6. Reinstall all components previously removed.
Figure 8.1, Upper Louver and Lower Louver Removal
MOUNTING
NUTS
(2 EACH SIDE)
Figure 8.2, Mounting Nuts Location
UPPER LOUVER
LOWER LOUVER
8.4 Safety Barrier Installation
1. Locate the (4) slots on the shroud (2 each side).
2. Align the tabs located on the back of the safety barrier with the
slots on the shroud.
3. Raise the safety barrier slightly into the slots and allow the tabs
to lower into position.
•
To remove safety screen: lift the screen up and out of slots.