9.4 #SL42-028 Optional Fan Kit
ATTENTION: Installation of this fan kit should be done only by a
qualified installer.
WARNING: Verify household breaker is shut off prior to working on
any electrical lines. Disconnect all electric power from fireplace before
performing any of these tasks.
1. Remove safety barrier, access cover, and glass frame assembly.
2. Disconnect wiring terminals from fan motors.
3. With the motor end of the fan’s right side facing down and to the
right, insert fan into chamber. Insert the fan at the far end of the
firebox.
4. When the motor end clears the fireplace face, turn the fan to the
left.
5. Rotate the top end down and to the right, lowering the fan into
control compartment.
6. Position fan as shown in Figure 9.4. As you rotate the fan towards
you, the upper edge of the fan discharge will lock behind the top
edge of fireplace air channel opening, securing fan into place.
DO NOT LET THE FAN REST ON ANY ELECTRICAL CORDS.
7. Repeat for the left fan, noting the fan rotation in steps above will
be opposite of the right fan.
8. Reattach wiring terminals to fan motors.
9. Plug the fan cord into the receptacle on the IFC control module.
10. Reinstall the glass frame assembly, access cover and safety
barrier.
Figure 9.4, Steps 3 and 4
Figure 9.5, Steps 5 through 9
#CLW-50 R.6 November 2021
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
ELECTRICAL INFORMATION
57