9.0 ELECTRICAL INFORMATION
WARNING: Do not use this fireplace if any part has been under water.
Immediately call a qualified service technician to inspect this appliance
and to replace any part of the control system and any gas control which
has been under water.
WARNING - Electrical Grounding Instructions: This appliance is
equipped with a three-prong (grounding) plug for your protection
against shock hazard and should be plugged directly into a properly
grounded three-prong receptacle. Do not cut or remove the grounding
prong from this plug.
9.1 Electrical Specifications
This appliance, when installed, must be electrically grounded in
accordance with local codes, or in the absence of local codes, with
the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
9.2 Wiring Requirements
•
The IFC System Module requires 120V of electricity and/or
batteries to operate.
•
Using the battery back-up will operate the burner only.
•
Optional fan component will not function on battery back up
power.
Figure 9.1, Wiring Schematics
M
ALE END
VARIABLE SPEED F
AN
[optional]
VARIABLE LIGHT
APPLIANCE GR
OUND ST
AR
BA
TTER
Y
PA
CK
885 PR
OFLA
ME
M
AIN ON/OFF
SWIT
CH
PIL
O
T
PIL
O
T
BURNER
FLA
ME
SENSOR
IGNITER
SW1 BUT
TON (RED
)
AUX (
ON/OFF)
[optional]
POWER VENT [optional]
#CLW-50 R.6 November 2021
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
ELECTRICAL INFORMATION
55