48
TROUBLESHOOTING
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#BAY-41-G R.9 Sept 2018
Issue
Cause
Solution
Pilot and burner extinguish
while in operation
No propane in tank
Check propane tank. Refill if necessary.
Incorrect glass assembly
installation
Section 8.1 Glass Frame Assembly on page 33
Incorrect vent cap installation
Adjust if necessary.
Vent cap blockage
Remove debris if necessary.
Improper pitch on horizontal
venting
¼ in. (6 mm) rise per foot (30 cm) is required on horizontal venting
Inner vent pipe leaking exhaust
gases back into firebox
Check for leaks and repair if necessary.
Excessive draft
Restrictor setting may need to be adjusted.
Soot appears on glass
Improper glass media placement
Section 8.4 Glass Media on page 34
Improper venturi setting
Venturi air shutter may need to be opened slightly to allow more air
into the gas mix. Section 11.2.1 Burner Venturi on page 45
Incorrect vent cap installation
Adjust if necessary.
Vent cap blockage
Remove debris if necessary.
Improper pitch on horizontal
venting
¼ in. (6 mm) rise per foot (30 cm) is required on horizontal venting
Flame burns blue and lifts
off burner
Improper venturi setting
Venturi air shutter may need to be opened slightly to allow more air
into the gas mix. Section 11.2.1 Burner Venturi on page 45
Incorrect vent cap installation
Adjust if necessary.
Blockage or leakage of the vent
system
Check the vent pipes for leaks, and the vent cap for debris. Repair the
vent pipes or remove debris from vent cap, if necessary.
No reaction to command
Battery back batteries or remote
control batteries low
Replace batteries.
No communication between
remote control and IFC module
Reprogram remote control to IFC module.
A maximum number of failed
ignitions or flame restorations
has been reached
Reset IFC module.