#BAY-41-G R.9 Sept 2018
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
OPERATING INSTRUCTIONS
39
10.1 Setup Proflame 2 IFC Module
1. Set the main ON/OFF rocker switch in the OFF position.
2. Install (4) AA batteries (included in the components packet) into
backup battery holder on the control module.
3. Install (3) AAA batteries (included in the components packet) in
the remote control battery bay, located at the base of the remote.
4. Connect the IFC Module to an AC power supply.
10.2 Initialize the Control System
IMPORTANT: Remove all packaging and combustible material from the
firebox before initializing the control system.
NOTE: Performing the next steps will initiate pilot start-up in manual
mode, where the pilot igniter will spark repeatedly. The pilot will ignite
if gas is supplied to the fireplace.
1. Locate the red SW1 button the IFC module.
2. Press the SW1 button. The IFC module will BEEP (3) times and
illuminate an amber LED. This indicates the receiver is ready to
synchronize with the transmitter.
3. Within (5) seconds, push the ON/OFF button on the remote
control. The receiver will BEEP (4) times to indicate the transmitter’s
command is accepted, and is set to the transmitter’s particular
code. The pilot will automatically ignite.
4. Press the remote control ON/OFF button again. The pilot will
extinguish, confirming the remote control command. The control
system is now initialized.
5. Set the main ON/OFF rocker switch to ON position for remote
control operation of the main burner and fireplace features.
10.3 Reset the System for
Manual Operation
1. Set the ON/OFF rocker switch to OFF position.
2. Press the red SWI button on the IFC module until it emits (3) beeps
and an amber LED is illuminated.
3. Within (5) seconds, press the red SWI button again. This will
close synchronization with the remote control. The pilot will
automatically light.
•
Turn the main burner ON by setting the ON/OFF switch in ON
position. The main burner will only operate on HI.
•
Turn the main burner OFF by setting the ON/OFF switch in the
OFF position. The pilot will remain lit even if burner is turned off,
provided CPI mode is turned on.
10.4 Automatic Safety Restart
•
This system will execute an automatic turn OFF command for
approximately (5) seconds within (24) hours of a continued pilot
flame ignition to perform a safety check. This allows the system to
verify correct safety functions.
•
After the turn OFF sequence is completed, the IFC module will re-
execute the latest command.
10.5 Backup Battery Operation
This appliance will operate on the backup battery pack when electric
power is interrupted, or in a power outage. The lifespan of the backup
batteries depend on various factors, such as the quality of the batteries,
number of ignitions, et cetera.
•
When the backup battery pack is low, the IFC module will emit a
double-beep while receiving an ON/OFF command.
•
No commands will be accepted after this alert until the back up
batteries are replaced.
•
Once replaced, the IFC module will emit a ‘beep’ as soon as it is
powered.
Figure 10.1, IFC Module
SW1
BUTTON
LEDs