26
VENTING
Hussong Mfg. Co., Inc. • Kozy Heat Fireplaces
#BAY-41-G R.9 Sept 2018
7.1.3 Install Exhaust and Combustion Air
Intake Collars to Fireplace Rear
7.1.4 Install Cover Plates to Fireplace Top
WARNING: The cover plates must be installed on the top of the
fireplace. DO NOT proceed with the fireplace installation until the vent
conversion is completed.
1) INSTALL 4” (101mm) EXHAUST COLLAR TO APPLIANCE REAR.
VERIFY GASKET IS IN PLACE. SECURE WITH (6) SCREWS PREVIOUSLY REMOVED.
2) INSTALL 6-5/8” (168mm) COMBUSTION AIR INTAKE COLLAR TO APPLIANCE REAR.
VERIFY GASKET IS IN PLACE. SECURE WITH (4) SCREWS PREVIOUSLY REMOVED.
3) INSERT TABS ON REAR COVER PLATE INTO SLOTS.
SECURE WITH (1) SCREW PREVIOUSLY REMOVED.
1) INSTALL EXAHUST COVER PLATE TO APPLIANCE TOP. VERIFY GASKET IS IN PLACE.
SECURE WITH (6) SCREWS PREVIOUSLY REMOVED.
2) INSTALL COMBUSTION AIR INTAKE COVER PLATE TO APPLIANCE TOP.
VERIFY GASKET IS IN PLACE.SECURE WITH (4) SCREWS PREVIOUSLY REMOVED.
3) INSERT TABS ON OUTER COVER PLATE INTO SLOTS ON APPLIANCE TOP.
SECURE WITH (1) SCREW PREVIOUSLY REMOVED.